Tightening
390
9836 3521 01
6.7.3.1 Errors
The Bolt result variables
Errors
and
RM Errors
can hold the errors listed below.
When reported in binary format the respective error variable occupies 16 bytes (128 bits) where each bit
represent an error. The bits are numbered 0 to 127 and are laid out as below:
Byte Offset
0
1
2
3
Error bit no.
31
24 23
16 15
8 7
0
Byte Offset
4
5
6
7
Error bit no
63
56 55
48 47
40 39
32
Byte Offset
8
9
10
11
Error bit no.
95
88 87
80 79
72 71
64
Byte Offset
12
13
14
15
Error bit no
127
120
119
112 111
104
103
96
Note!
If Type is set to "I8" then only first 8 bytes are included, that is errors 0 to 63.
Possible errors:
Mnemonic
Bit
no.
Description
ANGDIAG
0
Angle count test failed during a diagnostic step
SPFUNCTEST
1
Spindle functional test failed during a diagnostic step
STZODIAG
2
Static zero offset failed during a diagnostic step
DYNZODIAG
3
Dynamic zero offset failed during a diagnostic step
FLYZODIAG
4
Flying zero offset failed during a diagnostic step
TR
5
Fail safe Torque restriction exceeded
AR
6
Fail safe Angle restriction exceeded
TIR
7
Fail safe Time restriction exceeded
TCR
8
Torque
– Current restriction exceeded
CROSSTR
9
Cross thread restriction exceeded
CROSSGR
10
Cross gradient restriction exceeded
T1HR
11
Torque in window 1 too high from check
T2HR
12
Torque in window 2 too high from check
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...