Tightening
9836 3521 01
323
Diagram:
Angle
Torque
TH
TH
Torque High
OSHT
Overshoot time
TL
Torque Low
Step
TL
OSHT
Shut-off point
Peak
Torque
Result var.:
Peak T, Peak T1, Peak T2, Peak T3 (Peak torque).
Alarms:
Step peak torque high (PTH) and step peak torque low (PTL).
Trace
:
TH and TL are shown in trace as horizontal lines from step start to step stop when post step
check time has elapsed. The lines are only shown when Torque vs. Time is selected.