PAGE
12
Repair Instruction No. 169.2/94
PHE 24/26/30-Range
1 Insert the spring (8) and the retaining
disk (7).
2 Depress the retaining disk (7) and insert
the ball (6).
3 Fit the retaining ring (5) and the sliding
sleeve (4).
4 Depress the sliding sleeve and insert the
seal ring (3) into the pass.
5 Fit the spacer (2).
6 Push down the sliding sleeve and fit the
rubber (1).
Mounting the
SDS-plus
Reception
PHE 24 R
PHE 26 R
1
1
1 2
5
3 4
7
8
6
Mounting the
FIXTEC-reception
PHE 24 RX
PHE 30 RX 2
9
6
7
8
3
4 5
2 10
2
1
1
2
1 Press in the seal ring (2) with aid of a
sleeve (1) (service tool No. 4931 5990 38)
until it engages.
2 Fit the following parts in this order:
- washer (9)
- inner spring (8)
- outer spring (7)
- locking ring (6)
3 Depress the locking ring (6) and insert the
balls (4).
4 Insert the ejector ring (5).
5 Depress the locking ring (6) (take care that
the balls cannot fall out) and press in the
ejector ring (5) with a used SDS-plus
adapter.
F
Press a locking ring into the spindle in
order to secure the ejector when mounting
the locking sleeve (3).
6 Fix the locking sleeve (3).
7 Remove the locking ring fitted to secure
the ejector.
Carry out a test run and check for strange noises.
Carry out an electrical examination. (See chapter Electrical and Mechanical Test Instruction).
Test run and
electrical
examination
Summary of Contents for PHE 24 Series