![Atlas Copco ITB-A31-05-I06 Safety Information Manual Download Page 3](http://html1.mh-extra.com/html/atlas-copco/itb-a31-05-i06/itb-a31-05-i06_safety-information-manual_3002029003.webp)
ITB-A31-05-I06
Safety Information
© Atlas Copco Industrial Technique AB - 9834 5879 00
3
Technical Data
Product Data
Motor voltage
35 V d.c.
Motor power
1080 W
Speed
2972 r/min
Torque range
1 - 5 Nm (0.7 - 3.6 ft lb)
Weight
1.5 kg (3.3 lb)
Battery Compatibility
Accessory
Article nr.
Battery, 14V (2.5Ah)
4211 6130 02
Battery, 18V (2.5Ah)
4211 6030 85
Battery, 36V (2.5Ah)
4211 6030 86
Maximum Radio Output Power
Radio Technology
Frequency Range
(MHz)
Maximum Trans-
mit Power EIRP
(dBm)
Wi-Fi®
2402-2480
19.46
Wi-Fi®
5180-5320
20.37
Wi-Fi®
5500-5700
18.39
Bluetooth® wire-
less technology /
Bluetooth® Low
Energy
2402-2480
9.29
Wi-Fi® is a registered trademark of Wi-Fi Alliance®
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG,Inc.
Wireless LAN Information
Regulatory Do-
main
Band
TxChannels
ETSI
2.4 GHz
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1
36, 40, 44, 48
U-NII-2
52, 56, 60, 64
U-NII-2e
100, 104, 108, 112,
116, 120, 124, 128,
132, 136, 140
FCC/IC
2.4 GHz
1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1
36, 40, 44, 48
U-NII-2
52, 56, 60, 64
U-NII-2e
100, 104, 108, 112,
116, 132, 136, 140
U-NII-3
149, 153, 157, 161,
165
Charger Compatibility
Accessory
Article nr.
Flex charger
4211 6083 84
EU SAR value
EU SAR Value: 0.55
Charger Temperatures
Charger operating tempera-
ture
+5 to +40 °C
(+41 to +104 °F)
Ambient Temperature
Operating temperature, charge
+5 to +40 °C
(+41 to +104 °F)
Operating temperature, discharge
0 to +40 °C
(+32 to +104 °F)
Storage temperature
−20 to +40 °C
(−4 to +104 °F)
Cable Power Supply Unit Compatibility
Accessory
Article nr.
Power Supply Unit 950
8432084004
Power Supply Unit 950
8432084006
Product Power Source
This product can be used with either a battery, or with an
electrical power cable in combination with a power supply
unit.
Declarations
Liability
Many events in the operating environment may affect the
tightening process and shall require a validation of results. In
compliance with applicable standards and/or regulations, we
hereby require you to check the installed torque and rota-
tional direction after any event that can influence the tighten-
ing result. Examples of such events include but are not lim-
ited to:
• initial installation of the tooling system
• change of part batch, bolt, screw batch, tool, software,
configuration or environment
• change of air- or electrical connections
• change in line ergonomics, process, quality procedures
or practices
• changing of operator
• any other change that influences the result of the tighten-
ing process
The check should:
Summary of Contents for ITB-A31-05-I06
Page 67: ...ITB A31 05 I06 Safety Information Atlas Copco Industrial Technique AB 9834 5879 00 67 130 C...
Page 79: ...ITB A31 05 I06 Safety Information Atlas Copco Industrial Technique AB 9834 5879 00 79...
Page 126: ...Safety Information ITB A31 05 I06 126 Atlas Copco Industrial Technique AB 9834 5879 00...
Page 159: ...ITB A31 05 I06 Safety Information Atlas Copco Industrial Technique AB 9834 5879 00 159 RCD RCD...
Page 165: ...ITB A31 05 I06 Safety Information Atlas Copco Industrial Technique AB 9834 5879 00 165 130 C...
Page 167: ......