![Atlas Copco GA 11 VSD Instruction Book Download Page 78](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653078.webp)
9.4
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet temperature
˚C
20
Relative humidity
%
0
Working pressure
Limits
Maximum working pressure
Minimum working pressure
bar(e)
4
Maximum air inlet temperature
˚C
40
Minimum air inlet temperature
˚C
0
9.5
Compressor data
Note
All data specified below are valid at reference conditions; see section
GA11 VSD - 10 bar
Unit
Frequency
Hz
60
60
60
Number of compression stages
1
1
1
Normal effective working pressure
bar(e)
4
7
9.5
Maximum effective working pressure,
Workplace
bar(e)
7.5
7.5
10
Maximum motor shaft speed
rpm
4110
4110
3674
Minimum motor shaft speed
rpm
1074
1074
1074
Temperature of air leaving outlet valve
(approx.), Workplace
˚C
37
37
37
Power input, Workplace (60 Hz)
kW
11.8
14.2
14.2
Oil capacity, approx.
l
4.8
4.8
4.8
Sound pressure level, Workplace and
Workplace Full-Feature (according to
ISO 2151 (2004))
dB(A)
69/3
69/3
69/3
Instruction book
76
API161475