OnePower Line Interactive UPS 

 

 

APPENDIX B: SUPPORT

 27

 

FRANCAIS 

1.1 Introduction 

32

 

1.2 Vérification 

32

 

1.3 Dans la boîte 

32

 

1.4 Mise en place 

33

 

1.8 Facade 

35

 

1.9 Face arrière 

36

 

1.10

 

Changement de Batterie 

37

 

APPENDICE A: PROBLEMES

 39

 

A.1.1 Problèmes 

39

 

A.1.2 Probléme avec le Logiciel Upsilon 2000 

39

 

A.1.3 Batterie et ICS 

40

 

APPENDICE B: ASSISTANCE

 41

 

TECHNICAL FEATURES

 42

 

BACKUP TIME

 43

 

AVR

 43

 

 
 
 
 
 
 
 
 
 
 
 
A03-PS651_MX01 (V1.00 February 2007) 
 
 

Summary of Contents for Line Interactive UPS A03-PS651 _MX01

Page 1: ...Where solutions begin ISO 9001 2000 Certified Company OnePower Line Interactive UPS A03 PS651 650VA 375W MANUAL A03 PS651 _MX01 ...

Page 2: ...ntis land com For more detailed instructions on configuring and using this device please refer to the online manual FRANCAIS Ce produit est couvert par une garantie Atlantis Land On Site de 3 ans Pour des informations plus détaillées référez vous svp au site Web www atlantis land com DEUTSCH Dieses Produkt ist durch die Atlantis Land 3 Jahre On Site Garantie gedeckt Für weitere Informationen bezie...

Page 3: ...EMI 12 A 1 1 Problematiche dell UPS 12 A 1 2 Problematiche del Software Upsilon2000 13 A 1 3 Batterie e Circuito di Protezione in Ingresso ICS 14 APPENDICE B SUPPORTO OFFERTO 15 ENGLISH 1 1 Important Safety Instructions 18 1 2 Inspection 18 1 3 Package Contents 18 1 4 Placement 18 1 6 Connect telephone Network Surge protection and RS232 19 1 7 Operation Test 20 1 8 Front Panel Explanations 21 1 9 ...

Page 4: ...oîte 32 1 4 Mise en place 33 1 8 Facade 35 1 9 Face arrière 36 1 10 Changement de Batterie 37 APPENDICE A PROBLEMES 39 A 1 1 Problèmes 39 A 1 2 Probléme avec le Logiciel Upsilon 2000 39 A 1 3 Batterie et ICS 40 APPENDICE B ASSISTANCE 41 TECHNICAL FEATURES 42 BACKUP TIME 43 AVR 43 A03 PS651_MX01 V1 00 February 2007 ...

Page 5: ...di Atlantis Land spa Tutti i nomi di produttori e dei prodotti e qualsiasi marchio registrato o meno menzionati in questo manuale sono usati al solo scopo identificativo e rimangono proprietà esclusiva dei loro rispettivi proprietari CE Mark Warning Questo dispositivo appartiene alla classe B In un ambiente domestico il dispositivo può causare interferenze radio in questo caso è opportuno prendere...

Page 6: ...gare mai all uscita dell UPS fotocopiatrici stampanti laser utensili elettrici o qualsiasi altro tipo di carico induttivo Tale prodotto è stato progettato per essere collegato esclusivamente a personal computer Il non rispetto di queste indicazioni porterà all immediato decadimento della garanzia Attenzione Al fine di evitare rischi di incendi o shock elettrici disporre l apparato in ambiente indo...

Page 7: ...osse danneggiato La confezione in cartone è in materiale riciclabile e andrebbe conservata e utilizzata per proteggere il prodotto durante eventuali spedizioni 1 3 Contenuto della confezione Una volta aperta la confezione in cartone dovrebbero essere presenti i seguenti componenti OnePower Line Interactive UPS 650VA 375W CD Rom contenente il software UPSilon2000 Cavo RS232 Manuale di installazione...

Page 8: ...e Si ricorda inoltre che L UPS è da usarsi esclusivamente in ambienti chiusi indoor Deve essere collocato lontano da qualsiasi fonte di calore Non deve essere esposto direttamente ai raggi solari Deve essere collocato in ambienti con umidità controllata E opportuno lasciare almeno 15 cm dalle feritoie al fine di consentire un opportuna areazione Non va collocato a meno di 25cm dal Monitor al fine ...

Page 9: ...onamento del gruppo di continuità non collegare mai all uscita dell UPS fotocopiatrici stampanti laser utensili elettrici o qualsiasi altro tipo di carico induttivo se non nelle 2 prese schuko protette 1 6 Connessione PSTN Ethernet ed RS232 La protezione PSTN va utilizzata per proteggere i dispositivi a valle collegati alla porta F M T dai problemi elettrici entranti dalla linea telefonica collega...

Page 10: ...che il LED UNUSUAL verificare la batteria e o il carico condizione di overload 4 Una volta collegato il carico all UPS è possibile effettuare un test di corretto funzionamento A tal fine rimuovere il cavo che collega l UPS alla rete elettrica Il Led BATTERY si accenderà in arancione ed ogni 3 5 secondi simultaneamente partirà un beep acustico L intervento dell UPS permette al PC di continuare ad a...

Page 11: ...eve restare costante NORMAL 1 Acceso verde fisso quando il dispositivo è acceso e l alimentazione di rete è presente Spento quando l alimentazione di rete è assente BATTERY 2 Acceso Arancione quando l UPS funziona in modalità INVERTER e contemporaneamente il dispositivo emette un beep sonoro intermittente sempre ogni 3 5 secondi Quando la Batteria è prossima all esaurimento si accenderà anche UNUS...

Page 12: ...residua è inferiore al 30 viene emesso un segnale sonoro ogni secondo e si accenderà il led UNUSUAL Dopo qualche secondo se la rete elettrica continua Tenere alimentato il gruppo per almeno 10 ore affinché le batterie possano caricarsi completamente ATTENZIONE Quando la rete elettrica è ritenuta non adeguata l UPS passa in modalità batteria e se il carico collegato è sovradimensionato viene acceso...

Page 13: ... 2 2 presa Schuko di mantenimento Collegare a queste prese gli apparati che non devono essere alimentati dalla batteria in caso di black out o altre anomalie sulla rete elettrica 3 RJ11 RJ45 Jack Da utilizzarsi per la protezione delle anomalie provenienti della linea telefonica LAN 4 Pulsante di accensione 5 Led di segnalazione 6 Circuito di protezione in ingresso 7 Connettore RS232 collegare tram...

Page 14: ...ogi anelli o oggetti di metallo impugnare attrezzi con materiale isolante indossare guanti di gomma e stivali non appoggiare attrezzi o parti di metallo sopra la batteria All uscita dell UPS può esserci una tensione di 220V anche quando il gruppo è scollegato dalla rete Prima di iniziare la sostituzione della batteria è opportuno spegnere l UPS e staccarlo dalla rete elettrica 1 Posizionare il dis...

Page 15: ...OnePower Line Interactive IT A03 PS651 Pag 11 ATTENZIONE Una volta sconnessa la batteria il carico non viene protetto in caso mancasse l alimentazione di rete ...

Page 16: ...re il tasto reset 6 3 Controllare che sia propriamente collegato Nessun LED si accende nel pannello frontale 1 Le batterie sono completamente scariche 1 Lasciare il prodotto sotto carica per 24 ore e riprovare 2 Chiamare l assistenza tecnica di Atlantis Land Quando la rete elettrica è assente il buzzer suona continuamente ed il Led BATTERY UNUSUAL è acceso 1 Vericare il carico collegato 2 Batteria...

Page 17: ...lon2000 Situazione Azione Correttiva Come Installo il software in dotazione Una volta effettuato l avvio dell UPS connetterlo al PC tramite il cavo RS232 in dotazione A questo punto inserire il CD col software ed installare Upsilon2000 usando il codice seriale univoco presente sulla custodia del CD UPsilon2000 non rileva l UPS Cosa posso fare 1 Verificare che il cavo sia correttamente connesso 2 U...

Page 18: ... trovare la batteria per la sostituzione 1 Presso un qualunque negozio specializzato 2 Chiederla direttamente all assistenza tecnica di Atlantis Land Come verifico lo stato del Circuit Breaker Un ispezione esterna è sufficiente per valutarne lo stato Premere il pulsante per permettere all UPS di tornare a funzionare è opportuno considerare che l ICS ha cambiato stato per una qualche causa che andr...

Page 19: ...e prodotto presente sul retro dell ups che fornirà assistenza da lunedì al giovedì dalle 9 00 alle 13 00 e dalle 14 00 alle 18 00 Il venerdì dalle 9 00 alle 13 00 E possibile anche utilizzare il fax 02 93906161 la posta elettronica info atlantis land com oppure tecnici atlantis land com Atlantis Land SpA Viale De Gasperi 122 20017 Mazzo di Rho MI Tel 02 93907634 help desk Fax 02 93906161 Email inf...

Page 20: ...lation If this equipment does cause harmful interference to radio or television reception which can be checked by switching the equipment off and on the user should correct the interference by one or more of the following measures Move the receiving antenna to a different position Move the equipment and receiver apart Connect the equipment into an outlet on a different circuit Consult the dealer o...

Page 21: ...disconnected Caution Risk of electric shock Battery Circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching Caution The UPS is designed to be for use with computer loads only Do not connect a laser printer to the outlets Caution Do not try to repair the unit yourself contact your local supplier or your warranty will be void ...

Page 22: ... If any of the above items are missing please contact your reseller Inspect the UPS after take off the packaging if anything is broken please contact the vendor 1 4 Placement To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants This UPS system is designed for indoor use only Do not install the UPS under direct su...

Page 23: ...ake sure that all of the loads are switch On Caution Do not connect a laser printer to the outlets These UPS outlets provide battery power and surge protection to the equipment when utility voltage is outside acceptable limits 1 6 Connect telephone Surge protection and RS232 Connect a single line telephone or a 10 base T 100 base T network cable into the RJ 45 RJ 11 telephone network surge protect...

Page 24: ...s until hearing one short beep sound to switch the UPS on then UPS is in the displaying condition If use UPS for first time please let UPS operate for 10 hours emptily to charge battery so that battery can t be in low capacity 3 After switch on UPS in utility power mode press POWER button within 2 seconds and UPS perform a self test on the battery capacity renew within 3 seconds 4 Connect your com...

Page 25: ...put watt please reduce some equipment or UPS will lock under backup power condition No output of UPS display OVERLOAD or FAULT 1 8 Front Panel Explanations On the front panel You can found 3 LED for an easy diagnostic LED Information Main Switch 4 To Control on off the UPS when Utility is normal To enable DC Start Function when Utility fails To enable DC Start properly you are recommended to conne...

Page 26: ...econds When the battery is low voltage Buzzer emits sound for every 1 seconds UNUSUAL 3 Red LED remains standstill when the Battery is failure when UPS is overload or short circuit when the battery is low voltage 1 9 Panel Explanations Number Explanations 1 UPS OUTPUT OUTLETS Provides output power to computer device 2 SURGE PROTECTION OUTLETS Provides a noise filtering ...

Page 27: ...T BREAKER Protects against UPS system overload 7 COMMUNICATION INTERFACE PORT Connect to the computer with the communication RS232 cable 8 UTILITY POWER INPUT LINE Connects to input utility power through the input power cord 1 10 Buzzer Explanation Buzzer Meaning When UPS is operating in normal utility power range buzzer emits no sound When Utility power is abnormal and UPS is in battery mode Buzz...

Page 28: ...ss the battery cover latch and remove the battery cover Step 1 Step2 and Step 3 2 Gently Pull the battery out of the UPS Step 4 3 Loosen the black wire from the negative Black terminal and red wire from the positive Red terminal Step 5 4 Connect the battery leads to the new battery small sparks at the battery connectors are normal during connection 5 Slide the battery into the UPS 6 Close gently t...

Page 29: ...n rated voltage 2 Input circuit breaker has been tripped 3 Power socket line isn t connected 1 Save the computer and switch off until is normal 2 Reset circuit breaker 3 Connect power socket line When utility power is off UPS automatically power off buzzer emits continuous alarm sound and display BATTERY and UNUSUAL 1 Overload 2 Battery is weak 3 Battery is broken 4 Battery charging circuit failur...

Page 30: ...nected 2 Use the original cable 3 Launch Upsilon2000 then click on INSTALLATION and check that TYPE OF COMMUNICATION is correct COM A 1 3 Battery and Input Circuit Breaker Situation Solution Backup time The battery backup time sometime called battery reserve time or battery autonomy is the length of time the battery will supply power to the load during a power failure You can check on the Appendix...

Page 31: ...hould contact the dealer where you bought this device If you have any other questions you can contact the Atlantis Land company directly at the following address Atlantis Land SpA Viale De Gasperi 122 20017 Mazzo di Rho MI Tel 39 02 93906085 39 02 93907634 help desk Fax 39 02 93906161 Email info atlantis land com or tecnici atlantis land com WWW http www atlantis land com ...

Page 32: ...OnePower Line Interactive UPS EN A03 PS651 Pag 28 ...

Page 33: ...droit de revoir le contenu de cette publication et d y apporter des modifications de temps en temps sans obligation d informer les utilisateurs de ces changements Nous avons fait tout notre possible afin d éviter la présence d erreurs dans le texte les images les tableaux présents dans ce manuel et dans le Cd Rom Cependant nous ne pouvons pas garantir l absence totale d erreurs et ou d omissions n...

Page 34: ...pas le produit lorsqu il est sous tension Ne soumettez l entretien qu à du personnel qualifié Les parties actives à l intérieur de cet UPS peuvent être à de fortes tensions même lorsque l alimentation secteur est déconnectée Le Circuit de la Batterie n est pas isolé de l entrée secteur une tension dangereuse peut être présente entre les bornes de la batterie et la terre Testez avant de toucher Att...

Page 35: ...lant porter gants en gomme et bottes ne pas toucher la batterie avec un objet en métal A la sortie de l UPS il peut y avoir une tension de 220V même lorsqu il n est pas connecté au réseau électrique Ne jamais ouvrir le couvercle Ne jamais introduire de liquide à l intérieur de la machine ...

Page 36: ...arantie n est plus valable si toutes les normes et les prescriptions indiquées dans ce manuel ne sont pas respectées 1 2 Vérification Vérifiez l UPS dès sa livraison Prévenez le transporteur ou le vendeur en cas de dommages L emballage est recyclable 1 3 Dans la boîte Une fois ouverte vous devriez trouver les éléments suivants OnePower Line Interactive UPS 650VA 375W CD Rom avec UPSilon200 Câble R...

Page 37: ...rature et l humidité sont contrôlées Cet UPS ne doit être utilisé qu à l intérieur Ne pas l installer à un endroit directement exposé au soleil la garantie serait annulée en cas de surchauffe de la batterie Afin d éliminer les surchauffes n obstruez aucune ouie de ventilation ne posez aucun objet sur l UPS et laissez une quinzaine de cms de distance avec le mur ...

Page 38: ...amais brancher à la sortie de l UPS des photocopieuses imprimantes laser outils électriques ou une quelconque charge inductive L UPS n est conçu que pour fonctionner avec un ordinateur 1 6 Connectez la protection Téléphone et le port RS232 Connectez le câble téléphonique dans la prise RJ 11 LINE de protection à l arrière de l UPS puis à la prise F M T le câble vers le Téléphone Fax Connectez le câ...

Page 39: ...sonore 4 Vérifiez le bon fonctionnement en utilisant normalement votre ordinateur 5 Vérifiez que votre UPS est bien initialisé pour supporter un fonctionnement continu 6 Pour eteindre l UPS appuyez sur le bouton M A jusqu à que la LED NORMAL est eteinte NOTE IMPORTANTE Avant tout usage il faut charger l UPS pendant au moins 10 heures 1 8 Facade Sur la facade du produit 3 Led indiquent l état de fo...

Page 40: ...USUAL est allumée lorsque la batterie est presque dechargée UNUSUAL 4 Allumée lorsque la batterie est presque dechargée Eclairage continu et alarme sonore continue en condition de surcharge Allumée lorsque l UPS est en panne 1 9 Face arrière Numéro Utilisation 1 Prise Protégée 2 x IEC320 2 x SCHUKO 2 Prise sortie Secours 2 x SCHUKO 3 Prise RJ11 Protection Téléphone Fax 4 Bouton M A ...

Page 41: ...me et bottes ne pas toucher la batterie avec un objet en métal A la sortie de l UPS il peut y avoir une tension de 220V même lorsqu il n est pas connecté au réseau électrique 1 Debranchez tous les cables reliés à l UPS Ouvrir l UPS 1 2 et 3 2 Tirez doucement les batteries vers l extérieur 4 3 Déconnectez le câble noir 5 puis le câble rouge 5 des bornes 4 Connectez les cables à la nouvelle batterie...

Page 42: ...OnePower Line Interactive UPS FR A03 PS651 Pag 38 ATTENTION Une fois la batterie déconnectée la charge n est plus protégée en cas de coupure de l alimentation électrique ...

Page 43: ...sez le bouton M A 2 Changez le fusible par un modèle identique 3 Reconnectez le câble Alarme sonore en utilisation normale combien un nouveau charge est connecté 1 Trop de charge 1 Retirez des charges peu importantes Aucune LED allumée en face avant 1 Consultez la Hot Line L UPS n assure plus un temps de sauvegarde normal 1 La batterie vient d être déchargée 2 La batterie est en fin de vie 1 Charg...

Page 44: ...ours backup time Durée pendant laquelle l UPS peut maintenir le bon focntionnement de la charge avant le déchargement complet de la batterie Cette durée dépend évidemment du type de charge Voir la section à la fin du manuel pour de plus amples détails Type de batterie utilisée dans l UPS 12VDC 7A h Durée de vie de la batterie Dépendante de l utilisation une bonne règle consiste à tester périodique...

Page 45: ...ra assistance du lundi au vendredi de 9 00 à 13 00 et 14 00 à 18 00 Vous pouvez aussi nous contacter par email tech fr atlantis land com Atlantis Land France 57 Rue d Amsterdam 75008 Paris Email tech fr atlantis land com Site Web http www atlantis land fr Important Pensez à consulter notre site Web pour prendre connaissance d éventuelles mises à jour du logiciel Upsilon 2000 clauses de garantie et...

Page 46: ...Low and Fault conditions Overload AC Buzzer continuously alarms for 30 seconds then Output is cut OFF and Input Circuit Breaker change status Overload Inverter Buzzer continuously alarms for 30 seconds then Output is cut OFF and Input Circuit Breaker change status Short Circuit INV Internal Fuse Short Circuit AC Input Circuit Breaker Battery Over drain Two stages Controlled Battery Low Warning Cut...

Page 47: ... 3 4 Ghz LCD 19 Power Rating VA 200 300 400 500 550 600 Power Rating W 120 180 240 300 330 375 Backup Time minute 16 9 5 4 3 2 AVR A03 PS651 Vin V AVR Vout V Note Vin 165 N A Inv 220 10 the UPS returns to AC output mode when AC input increase to 177V 165 Vin 205 Increase 15 190 Vout 235 206 Vin 249 N A 206 Vout 249 250 Vin 280 Decrease 11 223 Vout 250 Vin 280 N A Inv 220 10 The UPS returns to AC o...

Page 48: ...OnePower Line Interactive UPS A03 PS651 Pag 44 ...

Page 49: ...OnePower Line Interactive UPS A03 PS651 Pag 45 ...

Page 50: ...Where solutions begin Company certified ISO 9001 2000 Atlantis Land S p A Viale De Gasperi 122 Mazzo di Rho MI Italy info atlantis land com sales atlantis land com ...