10
3) Connecting the device
- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using a 3-wire
cable (Brown=Phase, Blue=Neutral, Black=Pilot
wire), through a connecting box. In damp premi-
ses, such as bathrooms and kitchens, install the
connecting box at least 25 cm from the ground.
- The installation must be equipped with a shutting-
off device in all poles having a distance of opening
of contact of at least 3 mm.
- Ground connection is forbidden.
Do not connect the pilot wire (
black
) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified elec-
trician using special tools.
- If a device pilots or is piloted by a 30mA differential (
e.g. bathroom
), the pilot wire supply must be
protected on this differential.
Panel heater cable
Live=brown
Neutral=blue
LIVE
NEUTRAL
Electricity
grid
Two possible cases
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
2
220-240V insulated cable
Note:
The pins
supplied with the
device are of the
standard type.
In case of a parti-
cular stand, use
appropriate pins.
4) How to fit the 2 pegs ?
1/Select the locations from the 4 to 6 available, depending on your machine’s output.
2/Push the peg into the hole in the channel.
3/Screw tight.
Power (W)
Measurement
(
A
)
Measurement
(
B
)
Measurement
(
C
)
600 +1000
1108
503
277
750 +1000
1433
262
900 +1000
1758
262
1
2
3
2
4
5
3
C
A
B
1