![Atlantic 526651 Installation Manual Download Page 54](http://html.mh-extra.com/html/atlantic/526651/526651_installation-manual_2999727054.webp)
Choose the temperature control to adjust: "
Heating
"
.
Two methods for adjusting the temperature control are available: flow temperature or gradient control.
●
Control using flow temperature
1
- Set "
Room T° influence
" then select "
Advanced settings
".
2
- Set "Display" to "
flow T°
". Set "
flow T° to -10°C
" and "
flow T° to +20°C
".
3
- Set "
Max flow T°
" and "
Min flow T°
".
1
Area 1 Heating
Room T° influence
Outd. T°
20
-10
65
40%
flow T°
Advanced settings
15
flow T° at -10°C
47°C
2
Display
flow T°
flow T° at -10°C
flow T° at +20°C
47°C
22°C
Area 1 Heating
Outd. T°
20
-10
15
65
flow T°
Next
3
Max flow T°
Min flow T°
Outd. T°
20
-10
15
65
55°C
17°C
flow T°
Complete
Area 1 Heating
●
Control using gradient
1
- Set "
Room T° influence
" then select "
Advanced settings
".
2
-Set "
Display
" to "
Gradient
". Set "
Gradient
" and "
Off-set
".
3
- Set "
Max flow T°
" and "
Min flow T°
".
1
Area 1 Heating
Room T° influence
Outd. T°
20
-10
65
40%
flow T°
Advanced settings
15
flow T° at -10°C
47°C
2
Display
Gradient
Gradient
Off-set
1
0°C
Area 1 Heating
Outd. T°
20
-10
15
65
flow T°
Next
3
Max flow T°
Min flow T°
Outd. T°
20
-10
15
65
55°C
17°C
flow T°
Complete
Area 1 Heating
●
Use 100% ambient temperature
If set to use 100%, adjust the radiator type.
Room T° influence
Emitters type
100%
Radiator
Area 1 Heating
Max flow T°
Min flow T°
55°C
17°C
Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options).