- 17 -
No.
Function
Configuration
or display range
Basic
setting
Heating time programme
(1)
(2)
, circuit 2
18
Pre-selection (day / week)
1 10
-
1
= Monday;
2
= Tuesday…
7
= Sunday;
8
= Monday to Friday;
9
= Saturday and Sunday
10
= Monday to Sunday (modifications are applied to the whole week)
19
1
st
phase of the selected day (start of comfort)
00:00 23:45
06:00
20
1
st
phase of the selected day (end of comfort)
00:15 24:00
22:00
21
2
nd
phase of the selected day (start of comfort)
00:00 23:45
- -:- -
22
2
nd
phase of the selected day (end of comfort)
00:15 24:00
- -:- -
23
3
rd
phase of the selected day (start of comfort)
00:00 23:45
- -:- -
24
3
rd
phase of the selected day (end of comfort)
00:15 24:00
- -:- -
DHW timer programme
(1)
25
Pre-selection (day / week)
1 10
-
1
= Monday;
2
= Tuesday…
7
= Sunday;
8
= Monday to Friday;
9
= Saturday and Sunday
10
= Monday to Sunday (modifications are applied to the whole week)
26
1
st
phase of the selected day (start of comfort)
00:00 23:45
00:00
27
1
st
phase of the selected day (end of comfort)
00:15 24:00
05:00
28
2
nd
phase of the selected day (start of comfort)
00:00 23:45
14:30
29
2
nd
phase of the selected day (end of comfort)
00:15 24:00
17:00
Heat pump
45
Switch from summer/winter (according to the
outdoor temperature)
15 30 °C
18 °C
When the average of the outdoor temperatures reaches 18°C, the regulator switches off the heating (as an economy
measure)
46
Legionella function
(1)
0 (off) 1 (on)
0
47
Correction of outdoor temperature sensor
- 5 5 °C
-
49
Assist mode
0 (Assist mode off)
1 (Assist mode on)
0
55
DHW boost
(1)
0 (off) 1 (on)
0
(1)
These parameters (or menus) may not appear. They depend on the appliance's configuration (on the options selected).
(2)
With a room thermostat, these menus are not shown on the user interface The time programme is only managed using the room thermostat in the
area considered
User manual "1634 - EN"