2.3 Positioning
The choice of the position is particularly important
as having to move it later is a delicate operation that
requires a qualified person.
Choose the position of the outdoor unit and the hydraulic
module after discussion with the client.
Respect the max. and min. distances between the
hydraulic module and the outdoor unit (
as the performances and life of the system depend on this.
2.4 Installing the outdoor unit
2.4.1 Installation precautions
"
The outdoor unit must only be installed
outdoors. If a shelter is required, it must have
large apertures on all 4 sides and respect the
space required for the installation (single phase
or three phase model
• Prefer a sunny location, sheltered from strong and
cold dominant winds.
• The appliance must be completely accessible for
subsequent installation and maintenance work (
).
• Ensure that the connections can be made easily with
the hydraulic module.
• The outdoor unit can be exposed to the weather,
however avoid installing it in places where it will
1000 mm
ou plus
200 mm
300 mm
200 mm
1000 mm ou plus
150 mm
150 mm
300 mm
Max. 500 mm
1000 mm
1500 mm
250 mm
250 mm
500 mm
Max. 500 mm
1500 mm ou plus
300 mm
500 mm
1500 mm ou plus
1500 mm
500 mm
Max. 300 mm
1500 mm
figure 13 -
Minimum installation clearance around the outdoor unit (all models)
Contact
your
energy
distributor
for the installation
constraints.
1000 mm
or more
1000 mm or more
1500 mm or more
1500 mm or more
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 16 -
Summary of Contents for 024200
Page 45: ... ...
Page 61: ... Installation and commissioning instructions 1485 EN 61 Heat pump alféa hybrid duo gas ...
Page 78: ... ...
Page 79: ... ...