1.6 Description
figure 6 -
Outdoor unit devices
Legend
1 -
High performance impeller and low noise level.
2 -
Electrical motor with variable "inverter" operation.
3 -
"Inverter" command module.
4 -
Control LEDs and buttons.
5 -
Connection terminal blocks (power supply and inter-connection).
6 -
Storage bottle for refrigerating fluid.
7 -
Cycle inversion valve.
8 -
Panels treated against corrosion.
9 -
Electronic pressure regulator.
10 -
"Inverter" compressor acoustically and thermally insulated.
11 -
Refrigerating connection taps (flare connector) with protective cover.
12 -
Condensate basin with drain hole
13 -
High performance exchange surface evaporator;
anti-corrosion treated hydrophilic aluminium fins and grooved copper tubes.
14 -
Solenoid valve for injection of liquid.
15 -
Electronic pressure regulator for injection of liquid.
16 -
"Inverter" compressor acoustically and thermally insulated with liquid injection port.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
"
hybrid duo gas 11 & 14+ single phase
"
hybrid duo gas 11, 14 & 16 3-phase
WO*K1**LCT
2
1
3
4
5
7
9
8
10
12
13
11
14
15
6
16
Installation and commissioning instructions "1485 - EN"
- 11 -
Heat pump alféa hybrid duo gas
Summary of Contents for 024200
Page 45: ... ...
Page 61: ... Installation and commissioning instructions 1485 EN 61 Heat pump alféa hybrid duo gas ...
Page 78: ... ...
Page 79: ... ...