SAFETY WARNINGS

SAFETY INSTRUCTIONS

•  All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit.
• 

The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to 

observe precautions could result in injury to people or damage to property.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death. 

 

This symbol/pictorial is used to identify the need to 

wear protective gloves.

!

Caution indicates a 

POTENTIALLY

 

hazardous situation, which, if not avoided, 

MAY

 result in minor or moderate injury.

Caution used without the safety alert symbol 

indicates a potentially hazardous situation, which, 

if not avoided, may result in property damage.

This symbol/pictorial is used to identify an 

ULTRAVIOLET LIGHT

 hazard.

This symbol/pictorial is used to identify an 

ELECTRICAL 

SHOCK

 or 

ELECTROCUTION

 hazard

.

Warning indicates a 

POTENTIALLY

  

hazardous situation, which, if not avoided, 

COULD

 result in death or serious injury.

This symbol/pictorial is used to identify the need to 

wear approved ultraviolet blocking eye wear.

This symbol/pictorial is used to identify the need to wear 

approved ultraviolet blocking face shield.

This symbol/pictorial is used to identify components 

which must not be disposed of in trash

Danger indicates an 

IMMINENTLY

  

hazardous situation, which, if not avoided, 

 

WILL

 result in death or serious injury.

SAFETY LABELS

CAUTION

Danger Label: Ultraviolet Radiation 

(00-0195A2)

Danger Label: Hazardous Voltage 

 

(00-0197A2)

It is the user’s responsibility to determine and validate 

the suitability of this equipment for use in the user’s 

system or process.

No warranty or representatio

n is made by the manufacturer 

with respect to suitability or performance of this equipment 

or to the results that may be expected from its use.
The user should periodically inspect, clean as necessary 

and confirm the presence and good legibility of the product 

safety labels. Contact the factory for replacement labels in 

the event that any of the labels are missing or illegible.

U

UV

V

ULTRAVIOLET 

RADIATION

Protect eyes and skin from 

direct and reflected radiation.

Turn off and disconnect

power before servicing.

HAZARDOUS

VOLTAGE

DANGER

00-0196A1

ULTRAVIOLET RADIATION

Protect eyes and skin from direct and reflected radiation.

Turn off and disconnect power before servicing.

HAZARDOUS VOLTAGE

DANGER

00-0199A1

U

UV

V

WARNING

No. 00-0195A2 

U

UV

V

ULTRAVIOLET

RADIATION

Protect eyes and skin

from direct and reflected

radiation.

DANGER

Turn off and disconnect

power before servicing.

HAZARDOUS

VOLTAGE

No. 00-0197A2

AIR & WATER

Part No. 00-0195A2 (

2.75 x 1.5)

Part No. 00-0197A2 (

2.75 x 1.5)

AIR

Part No. 00-0198A1 (1.25 x 3) 

This fixture is designed for use with germicidal

ultraviolet lamps and must be installed in 

compliance with competent technical directions 

so that the users eyes and bare skin will not be 

subjected to injurious radiation.

WARNING

No. 00-0198A1

AS OF MAY 2002 THESE LABELS ARE BEING USED ON ALL OUR PRODUCTS

Part No. 00-0196A1 (

2.5 x 2.25)

Part No. 00-0199A1 (

5 x 1.33)

  To guard against injury, basic safety precautions should be observed, including the following:

1. 

Read and follow 

ALL

 safety instructions.

 

  

Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal ultraviolet 

rays are harmful to the eyes and skin.

2.  Intended for indoor use only.
3. 

Do not alter design or construction.

4. 

Do not use this fixture for other than its intended purpose, as described in this manual.

5. 

  

Do not override safety interlock.

6. 

Do not mount under any source of moisture or condensation, such as humidifiers, cooling coils, etc.

7. 

Do not remove any labels or devices.

8. 

 

  

Do not operate without proper electrical ground.

9. 

Do not operate the unit if there is visible or suspected damage to the unit or, if applicable, there is damage 

 

to power cord and/or plug.

10. 

Keep inlet and outlet, of the blowers, clean and clear of debris.

11. 

  

Do not operate without access cover secured.

12. 

Stay clear of blowers, or other moving parts that can cause injuries.

13. 

Utility power supplied, to the unit, 

MUST

 match power requirements listed on the unit label.

14. 

 

  

Always disconnect power to the unit before performing any service or maintenance

.

15. 

Read and follow all notices and warnings on the unit.

16. 

SAVE THESE INSTRUCTIONS.

Summary of Contents for SANITAIRE RS140

Page 1: ...iolet Corporation Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance Models RS72 RS140 RS435 RSA760 Extensive Product Information Available at Ultraviol...

Page 2: ...tic Ultraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and...

Page 3: ...xpected from its use The user should periodically inspect clean as necessary and confirm the presence and good legibility of the product safety labels Contact the factory for replacement labels in the...

Page 4: ...on tabletops shelves etc and standard wall mounting brackets Models RS72 RS140 and RS435 only These brackets allow the SANITAIRE to be mounted to a wall or other vertical surface in either the vertic...

Page 5: ...6 foot line cord 1 STER L RAY Germicidal Ultraviolet Lamp 1 Standard Promate Wall Mounting Kit 1 Operating Instructions 1 Warranty Card The SANITAIRE Model RS435 includes 1 435 CFM displacement 4 lam...

Page 6: ...6 Dimensional Data Figure 2 Dimensional Data All specifications dimensional data etc are approximate and subject to change without notice...

Page 7: ...th the catches on the filter housing and draw tight 6 Plug power cord into the electrical outlet 7 Verify operation by safely viewing lamps through sight glass If the SANITAIRE is not operating proper...

Page 8: ...ion Figure 5 RS435 Bolt Hole Location 3 Following manufacturer s instructions prepare wall for mounting hardware installation 4 Locate and remove the molded rubber feet and 20 x long screws Attach wal...

Page 9: ...HIS TASK BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT SAFETY GLASSES OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenance Ultraviolet...

Page 10: ...the filter is contaminated with heavy grease concentrations wash filter with a detergent solution NOTE Follow all manufacturer s instructions and precautions for handling detergents The filter should...

Page 11: ...cUV com Website Ultraviolet com BuyUltraviolet com TROUBLESHOOTING Always disconnect power to the fixture before performing any service or maintenance Use personal protection equipment such long sleev...

Page 12: ...Ultraviolet output at 254nm at 100 hours and 80 F approximate All specifications dimensional data etc are approximate and subject to change without notice REPLACEMENT PARTS Table 3 Replacement Parts...

Page 13: ...LACEMENT PARTS Figure 6 Replacement Parts List for SANITAIRE Model RS72 RS140 Note Model RS72 has only 1 lamp 1 lampholder set and 1 ballast Figure 7 Replacement Parts List for SANITAIRE Model RS435 R...

Page 14: ...14 MAINTENANCE NOTES...

Page 15: ...15 MAINTENANCE NOTES...

Page 16: ...ll notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is...

Reviews: