SAFETY INSTRUCTIONS

  To guard against injury, basic safety precautions should be observed, including the following:

1. 

Read and follow 

ALL

 safety instructions.

2.   

 

  Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal 

ultraviolet rays are 

harmful 

to the eyes and skin.

3.  Intended for indoor use only.
4.  Do not alter design or construction.
5.  Do not use this sanitizer for other than its intended purpose, as described in this manual.
6.  Do not use this sanitizer in occupied areas. The supplied “

DANGER - DO NOT ENTER…

” sign(s) 

MUST

 be clearly 

displayed to warn against entering the area during the disinfection cycle without proper personal protection equipment.

7. 

Germicidal ultraviolet rays may break down plastic, rubber or other non-metallic materials, with 

inadequate resistance to ultraviolet. Shield all plastic, rubber or other non-metallic parts which may be exposed to direct or 

reflected germicidal ultraviolet rays.

8.  Do not remove any labels.
9. 

 

  Do not operate without proper electrical ground.

10. 

Do not operate the sanitizer if the power cord and/or plug are damaged, or if any other damage to the sanitizer is 

 

visible or suspected.

11. 

Utility power supplied to the sanitizer, 

MUST

 match power requirements listed on the sanitizer label.

12. 

 

  

Always disconnect power to the fixture before performing any service or maintenance

.

13. 

Read and follow all notices and warnings on the sanitizer.

14. 

SAVE THESE INSTRUCTIONS.

SAFETY WARNINGS

•  All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit.
• 

The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to 

observe precautions could result in injury to people or damage to property.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death. 

 

This symbol is used to identify the need to wear

 

protective gloves.

Caution indicates a 

POTENTIALLY

 

hazardous situation, which, if not avoided, 

MAY

 result in minor or moderate injury.

Caution used without the safety alert symbol 

indicates a potentially hazardous situation, which, 

if not avoided, may result in property damage.

Warning indicates a 

POTENTIALLY

  

hazardous situation, which, if not avoided, 

COULD

 result in death or serious injury.

This symbol is used to identify an 

ULTRAVIOLET LIGHT

 hazard.

This symbol is used to identify an 

ELECTRICAL 

SHOCK

 or 

ELECTROCUTION

 hazard.

This symbol is used to identify the need to wear 

approved ultraviolet blocking eyewear.

This symbol is used to identify the need to wear approved 

ultraviolet blocking face shield.

This symbol is used to identify components which must 

not be disposed of in trash

Danger indicates an

 IMMINENTLY  

hazardous situation, which, if not avoided, 

 

WILL

 result in death or serious injury.

Summary of Contents for Sanidyne 40-0634A

Page 1: ...duct Information Available at Ultraviolet com BuyUltraviolet com Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance 8 High Output UV Lamps with ArmorLit...

Page 2: ...NTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Prime Remote Po...

Page 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Page 4: ...equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be...

Page 5: ...ovide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent areas and surfaces from microorganisms Ultraviolet disinfection dosage is a f...

Page 6: ...de until ready for installation Carefully inspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until unit is assembled checked...

Page 7: ...is completed 2 Hour Buttons Up and down buttons are used to select treatment hours between 0 and 24 3 Minute Buttons Up and down buttons are used to select treatment minutes between 0 and 59 4 Start...

Page 8: ...s three icons at bottom which are Sound Off Vibrate Sound On 2 Indicator Light Glows RED when the device begins to turn on and during device charging Turns GREEN when fully charged 3 Treatment Time Se...

Page 9: ...to see percent of change 10 Settings Button Contains choices for a Settings Reset Operating Time or Clear Session Data b Set Date Time requires a PIN to reset See Setting Date and Time on Page 12 c S...

Page 10: ...ns supplied with the Sanidyne Prime Remote on all access doors to the area where treatment operation will take place It is the users responsibility to post signs or notices for all personnel and perso...

Page 11: ...econds remain on the countdown time the Sanidyne Prime Remote will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area of...

Page 12: ...someone near the Sanidyne Prime Remote the unit will immediately turn off and send an alarm to the Hand held Remote Controller and the Sanidyne Prime Remote If this event occurs the alarm can be turne...

Page 13: ...e Remote on each side of large fixed objects like a bed or table etc 2 Measure the longest distance from the Sanidyne Prime Remote to the farthest wall Use this length to compare to the Distance From...

Page 14: ...S BETWEEN CUFFS AND GLOVES AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Prime Remote have ArmorLiteTM Safe...

Page 15: ...fied and factory authorized personnel Table 1 Troubleshooting Problem Possible Cause Corrective Action Sanidyne Prime Remote not operating Power disconnected Check connections Fuse not operating Remov...

Page 16: ...ity Aging Measuring UV C Germicidal Fixture Leakage 2 Promate Safety Glasses Safety eyewear MUST be used as general purpose safety protection and for additional shielding from ultraviolet rays 3 Addit...

Page 17: ...Part No Part No 1 STER L RAY Germicidal Lamp 05 0892 05 0892 2 SureliteTM Ballast 10 0138 10 0138 3 Power Cord 35 1754 35 1767 4 PromateTM Face Shield Adjustable Headgear 00 0126 00 0126 5 PromateTM W...

Page 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 20: ...g warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or...