10. 

CAUTION:

 Plug water puri

fi

 er into approved ground fault circuit interrupt (GFCI) receptacle. Con

fi

 rm lamp operation 

indication at sight port. 

11.  Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing between the puri

fi

 er and 

point of use. This is done by introducing chlorine or other disinfectant solution directly into the puri

fi

 er chamber, a 100-

ppm of chlorine is suggested. With the disinfectant solution in the puri

fi

 er chamber, turn the ultraviolet puri

fi

 er on. Open the 

“downstream” outlet until a chlorine or disinfectant solution odor is noticed. Close the outlet and allow the disinfectant to 
remain in the plumbing for at least three (3) hours. Flush the plumbing with ultraviolet puri

fi

 ed water; allow the water to run 

for a minimum of 5 minutes before use (to ensure no chlorine or disinfectant solution smell can be detected), this will allow 
the chlorine or disinfectant solution to be 

fl

 ushed through the pipes. 

CAUTION: For added protection, a suitable drain pan must be installed under the puri

fi

 er. The drain pan must be 

plumbed to an adequate, free 

fl

 owing drain to prevent water damage in the event of a leak. There are numerous leak 

detection/

fl

 ood stop devices, available on the market today, designed to stop the 

fl

 ow of water, reducing the chance of 

water damage due to leakage. For more details regarding leak prevention and/or limiting damages due to leaks, please 
contact the factory.

I

NITIAL

 I

NSTALLATION

 

OF

 Q

UARTZ

 S

LEEVE

 M

ODEL

 MP49C 

(S

HIPPED

 W

ITHOUT

 Q

UARTZ

 S

LEEVE

 I

NSTALLED

)

SAFETY EQUIPMENT REQUIRED TO PERFORM TASK

        WARNING: Water Puri

fi

 er should NOT be installed or plumbed prior to following the instructions on this page.

NOTE: 

Some 

Mighty

Pure

®

 Model MP49C models are packed without a quartz sleeve installed in the water puri

fi

 er chamber 

and instead have a PVC pipe installed temporarily (for shipping purposes). Please follow these instructions if applicable.

1.  Pull off Easy-Off

 end caps from static gland nut on each end of the water puri

fi

 er chamber.

2.  Unscrew static gland nuts from each end of the chamber and remove Te

fl

 on

®

 washer and o-ring from both ends of PVC pipe.  

Set aside.

3.  Remove PVC pipe and discard (REMINDER: be sure that the Te

fl

 on

®

 washer and o-ring from both ends of PVC pipe are 

removed before discarding)

4. 

 

CAUTION: Broken Quartz is SHARP. It is recommended that protective goggles and gloves are worn when 

handling.

 Remove quartz sleeve from separate package inside the carton which had contained the water puri

fi

 er.

5.  Align the end of the quartz sleeve with the gland 

fi

 tting on the chamber (the quartz sleeve can be inserted into the chamber 

from either end of the water puri

fi

 er chamber).

6.  Carefully slide the quartz sleeve into the chamber guiding it through the gland 

fi

 tting. Make certain the quartz sleeve is 

aligned in the center of the chamber. Do not force the sleeve sideways. This will result with the quartz sleeve breaking.

7.  As the quartz sleeve nears the far end of the chamber, guide and support the quartz sleeve by inserting your 

fi

 nger through 

the far end gland 

fi

 tting and into the end of the quartz sleeve. This will minimize the possibility of accidental breakage as the 

quartz sleeve passes through the gland 

fi

 tting. 

8.  Center the quartz sleeve so equal lengths are protruding at each end past the gland 

fi

 ttings.

9.  Reassemble the o-rings (Figure 3), Te

fl

 on

®

 washers (Figure 3) and gland nuts (Figure 3) in the order shown in Figure. 

TAKE CARE NOT TO DAMAGE THE QUARTZ SLEEVE WHEN INSTALLING THE GLAND NUTS. STRIKING THE 
SLEEVE WITH THE GLAND NUT WILL BREAK THE END OF THE QUARTZ SLEEVE.

10.  Tighten the static gland nuts 

fi

 rmly by hand. 

DO NOT USE HAND TOOLS

. Using hand tools is likely to cause quartz 

sleeve to break.

11.  Proceed to the Lamp Installation or Replacement section of this manual to properly install the germicidal ultraviolet lamp in 

the water puri

fi

 er.  

  

Summary of Contents for Mighty Pure MP16A

Page 1: ...PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1376C October 2015 2015 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read an...

Page 2: ...INTENANCE NOTES 22 23 USER ASSISTANCE 24 WARRANTY 24 PATENT NOTICE 24 These instructions generally describe the installation operation and maintenance of the Mighty Pure line of water purifiers Models...

Page 3: ...operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warning...

Page 4: ...r and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port...

Page 5: ...should be located in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purif...

Page 6: ...cted to the cold water line only 5 Installation requires that a 5 micron sediment filter or finer be installed in line prior to the water purifier The sediment filter will stop or trap large particula...

Page 7: ...nstalled temporarily for shipping purposes Please follow these instructions if applicable 1 Pull off Easy Off end caps from static gland nut on each end of the water purifier chamber 2 Unscrew static...

Page 8: ...8 Figure 3 Initial Installation of Quartz Sleeve...

Page 9: ...lerts the user to any malfunction detected 6 Solenoid Valve Operated in conjunction with the Ultraviolet Monitor Safety Sensor or Time Delay Mechanism this valve prevents water flow through the water...

Page 10: ...still in operation On purifiers not equipped with the Ultraviolet Monitor lamp operation can be verified by a visible glow through the translucent sight port This provides an indication of lamp operat...

Page 11: ...to chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be...

Page 12: ...move Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that...

Page 13: ...of quartz sleeve hold the purifier vertically and shake The quartz fragments will break and drop out of the purifier through the gland fitting Flush water through chamber being careful to remove all...

Page 14: ...gent and rinse with clean water Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals Once the quar...

Page 15: ...or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR...

Page 16: ...perature 35 F 100 F 35 F 100 F 35 F 100 F 35 F 100 F Quartz Sleeve 1 1 1 1 Drain Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight...

Page 17: ...elay Mechanism MP16A through MP49C Quantum Thermal Optimizer MP16A through MP49C Solenoid Valve MP16A 1 2 through MP22A 3 4 MP36C 1 MP49C 1 1 2 MP49C 1 1 2 Sure Flo Flow Control Valve MP16A 3 4 MP22A...

Page 18: ...18 REPLACEMENT PARTS Mighty Pure MODELS MP16A MP22A Figure 8 Exploded View MP16A MP22A...

Page 19: ...Quartz Sleeve 1 15 1111A 1 15 1112A 10 Sight Port Plug 1 30 1075 1 30 1075 11 Drain Plug 1 27 1216 1 27 1216 12 Speed Nut 6 32 2 50 1314 2 50 1314 13A Ballast 120v 60Hz 1 10 0137 1 10 0137 13B Ballas...

Page 20: ...20 Mighty Pure MODELS MP36C MP49C Figure 9 Exploded View MP36C MP49C...

Page 21: ...465G4 1 25 1465F5 12 Drain Plug 1 27 1216 1 27 1216 13 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 14 Lock Washer 1 4 4 50 1321 4 50 1321 15 Flat Washer 1 4 4 50 1317 4 50 1317 16 Ballast Housing Cove...

Page 22: ...22 MAINTENANCE NOTES...

Page 23: ...23 MAINTENANCE NOTES...

Page 24: ...een made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be con...

Reviews: