ATL User Guide
OM25 O
Optical M
Modem
56
8.4
DC POWER INLET
DC power is fed in via the three-pin socket on the rear panel. The cable assembly is shown in
section 8.5. A connection from CGND to earth is required for ESD protection of the unit.
Mating connector
Molex Minifit Junior Receptacle
Molex Part Number: 39-01-4031
Molex female contact
Molex Part Number: 39-00-0039
8.5
DC MAINS CABLE
The DC Power Cable can be ordered from ATL, ATL Part Number 6/910/000/423 (See
ACCESSORIES).
Stripped &
Tinned
3,000mm
Pin
1
White
Red
Black
2
1
3
1
2
-48V
0V
3
CGND
WHITE
RED
BLACK
Summary of Contents for OM25