-15-

Operating Principle: • 

When one talks, all intercoms will hear

.

• 

To talk to other stations, press the talk/listen switch and

 

speak into the speaker/microphone.  Release talk switch to

 

listen.

• 

Pressing the call button on remote 

A or B provides a

 

contact closure for an attention

‑getting auxiliary signaling

 

device, e.g. a strobe light.

NOTES: 1.

 

Speaker/Microphone

2.

 

Of

f/On/Speaker V

olume 

Control

3.

 

Listen/T

alk Switch

4.

 

“Call” T

one 

Switch

5.

 

Customer

‑Supplied 

Auxiliary Signaling Device (e.g., strobe

 

light)

Power

 

Remote A

  

Remote B

 

  12

‑18VDC

 

      

‑‑ 

 

AD

‑26

‑3

120V

 50/60Hz

 

AD

‑28X

‑MV

 

AD

‑27

‑3

 

22

‑30VDC

 

AD

‑28X

‑MV

 

AD

‑56

‑3

 

240V

 50/60Hz

 

AD

‑28X

‑MV

 

AD

‑57

‑3

 

 

POWER CONNECTIONS (Remote B): BLK

 

+DC Power

 

12/24V

 Models

 

 

HOT

 

120/240V

 Models

WHT

 

Common

 

12/24V

 Models

 

 

Neutral

 

120/240V

 Models

GRN

 

Earth Ground

 

120/240V

 Models only

Reminders: • 

Before installing remote intercoms, precautions should be taken to prevent feedback between two or more remotes in close proximity and acoustically reflective areas.

• 

16–20 gauge low voltage audio cable. 

Twisted pair not required.

• 

Shielded audio cable not required unless operating in high electromagnetic fields. Ground one end of the shield to earth ground.

• 

Audio and power cables are not supplied with 

AD

‑28X

‑MV

.

• 

The dry contacts can be used to switch an auxiliary audible or visual signaling device when the call button is depressed. 

The maximum ratings for the dry contacts are 0.5 amps @ 125V

AC and 1.25 amps 

@ 24VDC. 

This method assures a call is received even when the volume on one of the intercoms is turned all the way down.

11

290A4725-1

1

10

9

8

7

6

5

4

3

2

1

DR

Y CONT

ACT

FOR CALL

AUDIO (-)

AUDIO (+)

REMOTE

GROUND (-)

24VDC (+)

NEUTRAL

HOT

EAR

TH GROUND

AC

1K

1W

ATT

REMOTE A

1

3

2

4

BLK

AUDIO CABLE

TO OTHER INTERCOMS

AUDIO LINE

AUDIO LINE

RED

WHT

POWER

POWER

GRN

REMOTE B

POWER

AUXILIAR

Y

SIGNALING DEVICE

5

SEE POWER CONNECTIONS

BLK WHT GRN

*

*

1

3

2

4

AUXILIAR

Y

SIGNALING DEVICE

5

ATKINSON DYNAMICS

UNIVERSITY

 P

ARK, IL

 USA

A FEDERAL

 SIGNAL

 COMP

ANY

ATKINSON DYNAMICS

UNIVERSITY

 P

ARK, IL

 USA

A FEDERAL

 SIGNAL

 COMP

ANY

Summary of Contents for AD-28X-MV

Page 1: ...Atkinson Dynamics Intercom Model AD 28X MV Installation and Service Instructions 2561925 REV B1 1014 Printed in U S A...

Page 2: ......

Page 3: ...communications device designed for in dustrial applications Nominal operating voltages include 120 240VAC 50 60Hz and 24VDC Voltage changes for the 120 240VAC are internally switch selectable and the...

Page 4: ...ain wiring diagrams of typical intercom configurations REMOTE CONTROL Remote control is used to change the operation mode of a remote intercom from listen to talk or from talk to listen upon activatio...

Page 5: ...tect the audio lines and the remote control line The intercom must have Earth Ground terminated to it to ensure surge protection The output amplifier of the AD 28X MV offers full short circuit protect...

Page 6: ...roying them Before attempting to install the intercom be sure that all parts listed in the KIT CONTENTS LIST have been supplied C Kit Contents List Qty Description Part Number 1 Wiring block 140A326 0...

Page 7: ...VAC The switch is factory set for the intercom to operate on 120VAC see Figure 6 See figures 7 through 13 for typical intercom configurations The Model AD 28X MV s circuits are not nonincendive field...

Page 8: ...mber PC Board AD 28X MV K2001915 02 Kit potentiometer with on off switch K8590236 Kit toggle switch K8590298 Kit push button switch K8590241 Knob pot K141A129 Rubber boot toggle switch K288801 Rubber...

Page 9: ...ush up to listen 2 1 A Push down to talk 7 290A4725 01 ATKINSON DYNAMICS UNIVERSITY PARK IL USA A FEDERAL SIGNAL COMPANY A 290A4725 02 ATKINSON DYNAMICS UNIVERSITY PARK IL USA A FEDERAL SIGNAL COMPANY...

Page 10: ...Ground NOTE Terminal Block accepts 10 22 AWG wire B Dry contact H 24 VDC in out C For call I Neutral D Audio J Hot E Audio K Earth ground F Remote control L 120 240VAC in 290A4725 03 BACK VIEW ORANGE...

Page 11: ...s 2 Positive supply conductor must be fused at source with 1 2 A fuse or a power limited source must be used 290A4725 05 6 50 16 5 cm 41 1 cm WIDE 2 HOLES C A 5 68 14 6 cm 3 88 9 9 cm 4 84 12 3 cm 9 8...

Page 12: ...Remote control G Ground H 24VDC in out 6 I Neutral J Hot K Earth ground L 120 240VAC in M Master slave N To control panel O Speaker plug 290A4725 06 J2 J1 J3 F1 J4 J6 J7 J5 1 2A 250V 240VAC 120VAC MAS...

Page 13: ...switch to listen NOTES 1 Speaker Microphone 2 Off On Speaker Volume Control 3 Talk Listen Switch 4 Call Tone Switch 5 3 conductor 16 22 gauge cable Use shielded cable in electrically noisy areas Grou...

Page 14: ...ase talk switch to listen NOTES 1 Speaker Microphone 2 Off On Speaker Volume Control 3 Talk Listen Switch 4 Call Tone Switch Power Remote A Remote B 12 18VDC AD 26A 120V 50 60Hz AD 28X MV AD 27A 22 30...

Page 15: ...Slave talks to master hands free without having to press a talk switch When any master talks slave hears Other masters will hear To talk into master press talk switch and speak into speaker microphone...

Page 16: ...ns Operating Principle Masters normally listen to slave Slave talks to master hands free without having to press a talk switch When any master talks slave hears Other masters will hear To talk into ma...

Page 17: ...e remotes in close proximity and acoustically reflective areas 16 20 gauge low voltage audio cable Twisted pair not required Shielded audio cable not required unless operating in high electromagnetic...

Page 18: ...peaker microphone Release talk switch to listen NOTES 1 Speaker Microphone 2 Off On Speaker volume control 3 Press to talk Switch 4 Call Tone Switch 5 Desk Set speaker microphone is mounted on hand se...

Page 19: ...listen switch and speak into the speaker microphone Release talk switch to listen 3 For Remote A to talk to other stations press PTT button on handset and talk into handset microphone Reminders Befor...

Page 20: ...blank page...

Reviews: