20
ATIM_ACW-MR2-EX_UG_EN_V1.1
b)
Downlink frames configuration
This functionality is available on the ACW-MR2, fulfilling the following conditions:
Version
Product Software
SIGFOX
Not available
LoRaWAN
V2.2.4
Or superior
Downlink operation mode is explained in the ATIM_ACW-DLConfig_UG_FR_v1.1 document, related to
version V1.1 of Downlink protocol ATIM.
Downlink protocol ATIM V1.1, shared between all ACW Product Line devices, describes how to realize
the following actions:
•
Ask for an ACW products restart
•
Obtain product information
•
Ask for a factory settings reconfiguration
•
Obtain the actual configuration parameters of a product
Specific parameters of ACW-MR2 are the one mentioned bellow:
•
Life frame emission frequency
Parameter Code (1 octet)
Parameter Value (2 octets)
0x03
Possible values are:
0x04 = every 10 minutes
0x05 = every hours
0x0A = every 2 hours
0x0B = every 4 hours
0x0C = every 8 hours
0x06 or 0x09 = once a day
0x0D = every 2 days
0x0E = every 3days
0x0F = every 4 days
0x07 = every 7 days
0x08 = every 30 days
•
Operating mode
Parameter Code (1 octet)
Parameter Value (2 octets)
0x0A
Possible values are:
0x00 = standard meter reading with emission every 10 minutes
0x01 = standard meter reading with emission every 6 hours