background image

 

 

ATIM Radiocommunications 

Chemin des Guillets 

38250 Villard-de-Lans, France 

www.atim.com 

[email protected] 

 

 

 

Concerned model:  

AGT/INDUS2

 

ATIM Cloud Wireless 

LoRaWAN Gateway                                  

Modbus & MQTT                     

User Guide 

 

Summary of Contents for AGT/INDUS2

Page 1: ...ATIM Radiocommunications Chemin des Guillets 38250 Villard de Lans France www atim com contact atim com Concerned model AGT INDUS2 ATIM Cloud Wireless LoRaWAN Gateway Modbus MQTT User Guide...

Page 2: ...ndations 4 Radio 5 Presentation 6 Connection to the gateway 7 a LAN tab 8 b MQTT tab 11 c MODBUS tab 12 MODBUS server 13 a DevEUI 14 b Timestamp 14 c Payload 14 Example 1 15 Example 2 16 Example 3 16...

Page 3: ..._EN_V1 2 Document version history Version Date Description Author Concerned software version 1 0 07 03 2022 Document creation JA 1 1 30 03 2022 NTP server time synchronization JA 1 2 16 06 2022 WIFI h...

Page 4: ...ange without warning and does not represent a commitment on the part of ATIM Trademarks and copyright ATIM ACW ATIM Cloud Wireless and ARM Advanced Radio Modem are registered trademarks of ATIM SARL i...

Page 5: ...Article 3 1b of the 1999 5 EC Directive EN 301489 3 v1 4 1 EN 301489 1 V1 9 2 3 Efficient use of the radio frequency spectrum Art 3 2 of the 1999 5 EC Directive ETSI EN300 220 2 v2 4 1 and EN300 220...

Page 6: ...y at no cost and with no authorization required for industrial scientific and medical applications IMPORTANT NOTE Basic IT network knowledge is required to set up ATIM LoRaWAN gateways Contact your IT...

Page 7: ...ages can then be forwarded using either MQTT protocol MODBUS TCP protocol When 1gate Gateway is configured in MQTT it behaves as a MQTT client and publishes uplink messages to an external MQTT broker...

Page 8: ...nce connected the gateway configuration page can be accessed through a web page using the default IP address 192 168 1 1 Configuration changes can be made from this webpage Options can be changed with...

Page 9: ...ay to an existing ethernet network Two methods are possible for the gateway to get an IP address STATIC or DHCP Static addressing gateway will set a specific IP address for that Static IP address Netm...

Page 10: ...P address Gateway hostname Gateway hostname is unique and composed of the EMAC address with format below 1gate EMAC address NOTE EMAC is written on gateway label To access configuration webpage open a...

Page 11: ...WPA KEY written on gateway label Once connected to gateway WIFI the configuration page can be accessed with IP address 192 168 1 1 IMPORTANT NOTE Activating WIFI hotspot can result in IP conflicts Ti...

Page 12: ...M_1GATE_INDUS2_UG_EN_V1 2 b MQTT tab MQTT tab can be used to fill MQTT broker information When integration is set to MQTT then all fields must be filled so that the gateway can connect to remote MQTT...

Page 13: ...TE_INDUS2_UG_EN_V1 2 c MODBUS tab MODBUS tab can be used to see all devices registered and activated in the gateway The Last seen field indicates the date of the last uplink message that has been sent...

Page 14: ...UI 70b3d59ba000a761 Timestamp 1416020f090739 Data payload 10cea0cea64 For each part data is stacked on the right which implies that lot of registers are set to zero particularly if payload is short Wh...

Page 15: ...i e year month hour 001415070d140014 can be decoded as below Register Byte Description Hexadecimal Decimal Register 4 Byte 4 1 NC 00 Byte 4 2 Century 14 20 Register 5 Byte 5 1 Year 15 21 Byte 5 2 Mon...

Page 16: ...e product device registered Please see specific product documentation Example 1 MR4 configured with 2 counters devEUI 70B3D59BA000C27E and payload below To extract counter 1 registers 45 46 and 47 mus...

Page 17: ...00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 00 00 00 00 00 00 00 00 00 00 00 00...

Page 18: ...he LAN tab Port is 502 Slave ID is not specific since MODBUS server should respond to any slave ID Time Out can be left to 1000 Mode HEXADECIMAL Register the address corresponding to the device for ex...

Page 19: ...n page open a web browser and enter the IP address of the gateway followed by 8080 port Alternatively the gateway hostname can be used such as shown previously To connect to Chirpstack enter the defau...

Page 20: ...in the list For security reason OTAA Over The Air Activation method is used to add devices Two IDs are necessary for that A 8 bytes device EUI The 16 bytes application key attached to the devEUI To a...

Page 21: ...20 ATIM_1GATE_INDUS2_UG_EN_V1 2 In the next page complete Application Key field and confirm clicking on SET DEVICE KEYS...

Page 22: ...tion Device activity can be seen from DEVICE DATA tab Diverse events can be seen for debug and commissioning purposes join device join request to connect to gateway network up uplink message all field...

Page 23: ...ck However hexadecimal encoded payload is displayed under the data_hex field NOTE It is also possible to register devices using ABP method however it is necessary to create a new device profile to do...

Page 24: ...rt dedicated webpage IMPORTANT NOTE ATIM provides you with a gateway but not the driver s license that goes with it you must learn how to use and program it For technical questions concerning the Pack...

Reviews: