ENG - Manual of installation, use and maintenance.
210-0352_libretto_WHC_ATI_eng.docx
17
Jan-19
18.
GAS CONNECTION
Connect the gas supply line to the thread fitting of the appliance by means of a removable rigid connection: the gas pipe must
exit through the slot of the appliance. The gas connection is G 3/4 "and it is covered by a red protection cap. It is recommended
to foresee a gas interception manual tap near the appliance along the pipeline in an easily accessible position. See in the picture
below, the gas connection and the slot for the tube passage.
The device is delivered with the injector assembly set for G20 - 20mbar gas (factory assembled with ref. 180-0026). In case of
different gas such as G25 or G31, it will be necessary to purchase the related injector assembly (see the reference in the table
here below).
OTHER GAS TYPES
gas type
G20 - 20 mbar
G25 - 25 mbar
G31 - 37 mbar
Ref. for the injector
assembly
180-0026
180-0027
180-0028
Check the whole gas pipeline for tightness and make sure that it was performed in accordance with the regulations in force on
gas system (see SAFETY AND INSTALLATION LOCAL REGULATIONS).
19.
ELECTRICAL CONNECTIONS
The appliance is supplied without mains plug: it must be mounted during the first installation.
Connect electrically to a 230V-50Hz single-phase power network and to an efficient earthing system. The connection has to be a
polarized one. The appliance cable is composed of three cables having distinct colours: observe the table below to identify the
correct polarization. PHASE LINE AND NEUTRAL OF THE PLUG must correspond to the PHASE LINE AND NEUTRAL OF THE
ELECTRICAL OUTLET.
Neutral
Phase line
green yellow
blue
Brown
Foresee near the appliance a bipolar switch in case of need to fully stop the appliance. Connect the power cable of the
appliance, taking care to comply with the electrical standards of the country in which the appliance is installed. In case of
replacement of the power cable, use a cable with the same specification (cable H05 VV-F - 3x0.75).
Warning: the device is not protected against the effects caused by lightning. Before performing any work on the electrical
components of the appliance, first disconnect it from the electrical power supply using the bipolar switch.
THE INSTALLATION IS COMPLETED AND THE APPLIANCE IS READY TO BE TURNED ON AND ADJUSTED