UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
19
Ed 2021-02
20.
GAS CHANGE
To change the gas, use only the special gas conversion kit prepared by the manufacturer, indicated in the table below, carefully
following the following instructions contained in the kit.
Device
SX160
SX220
SX300
SX400
SX600
SX800
G20
Kit code
AKMETSX160
AKMETSX220
AKMETSX300
AKMETSX400
AKMETSX600
AKMETSX800
P. entrance
20 mbar
20 mbar
20 mbar
20 mbar
20 mbar
20 mbar
P. output
12.2 mbar
12.5 mbar
12.5 mbar
12 mbar
13 mbar
12.5 mbar
G31
Kit code
AKPROSX160
AKPROSX220
AKPROSX300
AKPROSX400
AKPROSX600
AKPROSX800
P. entry
37 mbar
37 mbar
37 mbar
37 mbar
37 mbar
37 mbar
P. output
27.5 mbar
25 mbar
27.5 mbar
27.5 mbar
27.5 mbar
27.5 mbar
Model
SX160
1)
Switch off the appliance, close the gas interception valve and disconnect the power supply
2)
Remove the burner door (A) and the insulating material (B)
TRANSFORMATION OF GAS SUPPLY
TO PROPANE G31
TRANSFORMATION OF GAS SUPPLY
TO METHANE G20
3)
Unscrew the 4 screws (C), position the mask
(D) in front of the burners and tighten the
screws (C)
3)
Unscrew the 4 screws (C), remove the mask (D)
in front of the burners and tighten the screws
(C)
4)
Replace the injectors (E). Be careful not to lose the sealing washers
5)
Start up the appliance and check the tightness of the gas circuit with a special spray
6)
Put the burner door (A) and the insulating material (B) back in their original positions and tighten
with the fixing screws.
7)
Adjust the burner pressure, according to the indicated value, using the REG screw on the gas valve.
The P.OUT pressure point can be used to check the value
8)
Attach the label contained in the kit to indicate the new type of gas supply