ATI Technologies PULSE-8 Manual Download Page 5

PULSE-8
MASTER PULSATION
CONTROL: 

3

Channel Indicators: 

Illuminate when 

channel is on

Ratio Select Buttons:

Used in conjunction with

the Up/Down buttons,

Ratio 1 selects channels 1 

and 3, whilst Ratio 2 selects

channels 2 and 4.

Hold both buttons down and 

switch from up (STAND-BY) to ON

to enter the Access mode. 

Mode Select Switch:

In the up (STAND-BY) position,  the 

displays extinguish and pulsation reverts 

to 50/50 ratio setting. Switched to ON, 

the displays illuminate and  pulsation 

starts using the data setup.

Use the switch in combination with other 

buttons to select different program-ming 

modes are available.

Reset Indicator:

Illuminates during a
manual reset or if 
programmed data is
lost.

Up and Down Buttons:

 Used to increase or

decrease the frequency and ratio settings.
Held down together whilst switching the Mode 
Select Switch from up (STAND-BY) to ON, the 
duty cycle is inverted.

Frequency Display:

Displays the frequency setting in the range 30 to 120 

pulses per minute  (ppm). The default setting is 40ppm.

Frequency Button:

 

Press and hold whilst using the Up/Down buttons to 

increase or decrease the frequency in Access mode. Select 

STAND-BY, hold the Frequency button down and select ON 

to revert to default settings.

Access Mode
Indicator:

Illuminates during 
ACCESS mode whilst 
the machine parameters
are being entered.

Split Indicator:

 Illuminates when different ratios have 
been selected for channel pairs 1+3 and 
2+4.

Invert Indicator:

Illuminates when the On and OFF periods 
within a cycle have been swapped.
Used for normally ON solenoid valves.

Ratio Display:

Displays the ON 
period of a cycle as 
a percentage of the 
complete cycle.
For example, if the 
display shows 60, 
the appropriate 
channel will be ON 
for 60% of the cycle 
and OFF for 40%.

Access for Solenoid

 Valve cables

Use 2.5csa.

Mains cable
 entry gland

Emergency Battery 

Connectors 12v or 24v

_

+

Power Source
Switch

Emergency
Battery UP

Mains
DOWN

Ratio 1

Freq

s

s

Ratio 2

Pulse-8 Master Pulsation System

1                   

2                    

3                   

4                                                                                

ON

FREQUENCY                                                                                                                                          RATIO

ACCESS                          INVERT

 RESET                               SPLIT      

©

 A

TL

 A

g

ri

cu

ltu

ra

l T

e

ch

n

o

lo

g

Li

m

ite

d

: F

e

b

ru

a

ry

 2

0

0

6

Reviews: