Quick-Change
Installation and Operation Manual
Document #9620-20-c-dkgm dkft-03
Pinnacle Park
•
1031 Goodworth Drive
•
Apex, NC 27539
•
Tel: 919.772.0115
•
Fax: 919.772.8259
•
www.ati-ia.com
•
Email: info@ati-
ia.com
C - 26
8. Recommended Spare Parts and Accessories
Description
Part Number
DKG Master Module Assembly
9121-DKG-M
DKF Tool Module Assembly
9121-DKF-T
Optional Accessories
Closure Cap for Female Mini Receptacles
3690-0000049-00
See drawings in Section 10 of this manual for spare parts directly associated with the DKG-M/DKF-T
modules.
9. Specifications
DKG EtherNet/IP Master Module
Factory Default Configuration
I/P Address: 136.129.1.1
Subnet Mask: 255.255.0.0
Gateway: 0.0.0.0
Note: The DKG-M DKF-T modules conform to the
EtherNet/IP Adaptation of
CIP Specification, Edition 1.12; © 2011, ODVA
The DHCP option is factory set to “disabled”
Interface Connections
Logic and Input power: Mini, 4-Pin Male.
Ethernet: M12 D-Coded, 4-Pin Female
Integrated Tool Changer I/O: (4) @ 8mm, 3-Pin Female supporting Tool
Changer Locked, Unlocked and Ready-to-Lock proximity sensors, internal 3-
Pin pin block to transmit latch and unlatch signal to the solenoid Valve.
24VDC for control signals, 5A/24VDC for pass-through signals.
Current Draw
Power: 180mA @ 24VDC, Master only (Unlocked sensor “ON”, Locked,
RTL1 & RTL2 “OFF”)
Valve Power (switched Auxiliary Power): 250mA @ 24VDC, Solenoid Valve
Weight
2.05 lbs (0.93 kg)
DKF EtherNet/IP Tool Module
Interface Connections
Output Power: Mini, 4-Pin, Female.
Ethernet: M12 D-Coded, 4-Pin Female
TSI connector, M12, 4-Pin, Female.
24VDC for control signals, 5A/24VDC for pass-through signals.
Tool-ID: (1) Thumbwheel switch reading 0–9 positions (i.e., ten unique ID
values).
Factory Default Configuration
Tool-ID set to 1.
Weight
1.35 lbs (0.61 kg)