Audio inputs and outputs should be connected using the rear panel labels as a 
guide. HI outputs are all in phase with each other and in phase with the HI inputs.  
 

CAUTION 

 
Your Distribution Amplifier has active drivers for both HI and LO output terminals. 
DO  NOT  GROUND  either  HI  or  LO  terminals.  If  you  are  driving  a single  ended 
(unbalanced - one side grounded) high impedance or 600ohm load, it should be 
connected between either HI to GND or LO to GND. If you are driving a balanced 
load, connect it between HI and LO output terminals. It is generally unnecessary 
to  terminate  the  DA  with  a  600ohm  load  if  it  is  driving  a  high  impedance  input 
although  placing  a terminating  resistor  across  a  HI-Z  input  at  the  receiving  end 
will occasionally reduce RF pickup. 
 
 

ADJUSTMENTS 

 
It is sometimes difficult to maintain good noise performance when using a DA to 
drive  medium  level  console  (-20dBm)  or  IHF  (.1V)  equipment  inputs.  You  may 
have found it necessary in the past to insert attenuator networks between a DA 
and  medium  level  console  inputs  to  allow  the  DA  to  operate  at  a  high  enough 
output  level  to  maintain  a  good  signal  to  noise  ratio.  Your  DA  will  reduce  its 
already low output noise still further as you turn down its' gain. In the absence of 
high  RF  fields,  you  can  distribute  input  signals  as  low  as  -20dBm  to  multiple 
loads at 0 to -20dBm levels. 
 
 

MAINTENANCE 

 
Power supply voltages are + and - 15VDC nominal. 
 
IC  output  DC  Voltages  under  no signal; shorted input conditions  should  remain 
within .1V of ground. Greater deviation is an indication of IC or circuit problems. 
 
 

MODIFICATIONS 

 
230 VAC OPERATIONS 
 
Your DA is wired for 115 VAC, 50/60Hz operation unless otherwise requested at 
the  time  ordering.  It  can  be  modified  for  230  VAC  operations  by  removing  the 
power transformer primary jumpers J3 and J5 and inserting a jumper in J4. 
 
Different types of attachment plug or line cords may be required for connection to 
alternate supply voltages. 