5. CONSTRUCTION DESCRIPTION AND OPERATION 

The purpose of this device is to heat the domestic hot water in two different ways (see FIG_5-1.): 

A.  through  the  heat  exchange  between  the  engine  cooling  water  and  the  water  stored  in  the  tank.  Such  heat 

exchange is possible thanks to a heat exchanger. The engine cooling water circulates through a coil placed at the 
center of the tank to spread the heat evenly. 

B.  by means of an electric resistance (supplied as standard with the appliance). 

 
Main parts (see FIG_5-2.):  

1.  Storage  tank:  it  is  entirely  made  of  steel  submitted  internally  to  a  double  enamelling  treatment  that  is  a  vitreous 

coating cooked at over 850 °C. 

2.  External coating: aluminum; it is highly resistant to shocks and external solicitations, having at the same time a very 

pleasant design. 

3.  Thermal insulation: made  of expanded  polyurethane  with closed cells avoids  unnecessary  heat losses. In  this  way 

the heat loss by thermal inertia is reduced to 1 ° C per hour for a period of 24 hours. 

4.  Heat exchanger: it is made of enamelled iron and its exchange surface allows to exploit at best the heat of the engine 

cooling water and to get hot water also in extreme conditions (very small temperature differences).). 

5.  Electrical resistance: the device is equipped with an electric heating element to heat the water even when the boat 

engine is turned off (for example when the boat is on the dock). Material: Incoloy corrosion resistant alloy. 

6.  Thermostat: has two functions, namely 

a.  temperature control: interrupts the power supply to the heater element when reaching the set temperature 
b.  overtemperature safety: interrupts the power supply to the resistance in case of excessive water temperature. 
characteristics:  temperature  control:  0  °  C  -  60  °  C;  Differential  temperature:  about  9  °  C;  intervention 
temperature: 83 ° C; maximum current: 20 A 

7.  Cold  water  inlet  and  pressure  relief  valve  (it  protects  the  tank  from  possible  excessive  pressures  caused  by  the 

expansion of water during heating. Automatically, without the assistance of different energy from that of the hot fluid 
under  pressure,  discharge  a  quantity  of  fluid  such  as  to  prevent  them  from  being  exceeded  the  predetermined 
pressure and temperature limits to protect the storage tanks. Calibration: 800 kpa - 116 psi) 

8.  Hot water outlet  
10.  Mounting bracket  

 
6. GENERAL WARNINGS 

  The installation must be performed in accordance with current legislation, by a qualified person who can do, not only 

a proper set up of the device, but also the necessary tests before starting the water heater.  

  during the original installation and subsequent maintenance, follow the instructions in this booklet carefully. changes 

to any type of connection or failure to follow instructions will cause the warranty expires. 

  before the installation, maintenance or repair, remove the power supply unit.  

 

WARNING:  USE  THE  BOILER  ONLY  FOR  APPLICATIONS  IN  THIS  SECTION.  DO  NOT  USE  THIS 
EQUIPMENT  FOR  OTHER  TYPES  OF  OPERATION.  THE 

MANUFACTURER  DOESN’T

  ASSUME 

RESPONSIBILITY  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  CAUSED  BY  IMPROPER 
APPLIANCE. 

 
7. POSITION AND ASSEMBLY 

The device can be installed in any space, without limitation, subject to compliance with the instructions provided in section 1. 
GENERAL PRECAUTIONS. 
On the unit there are two fixing brackets (FIG_7-1). This way you get easy installation but stable and safe.  
The appliance must be installed  in such a  way that the heat exchanger and / or the electrical resistance  are placed in the 
lower  part  (FIG_7-2).  For  other  installations  not  covered  in  this  manual  and  for  installation  on  sloping  walls,  contact  our 
technical office. 
It is possible to install the device even on sloping walls (FIG_7-2)  

 

8. HYDRAULIC CONNECTIONS  

To extend the life of the appliance water quality must meet the following limits: 
 

1.  hardness comprised between 15 and 50 ° F (in 

particular, where the water has undergone a softening 
or desalination treatment)  

2.  chlorides comprised between 25 and 100 mg / l 
3.  PH between 6.5 and 9.5 
4.  conductivity between 400 and 1500mS / cm 

 
Minimum pressure water inlet: 70 kpa.  
Maximum  water  inlet  pressure:  750  kpa  (for  higher  inlet  pressures  is  necessary  to  mount  a  pressure  reducer  with 
compensation of inlet pressure; adjustable downstream pressure, max 700 kpa) 
Connect the appliance according to the following directions: 
 
 

 

Summary of Contents for BL22 Series

Page 1: ...210 0339 edizione 2017 12 BL22 BL30 BL45 BL60 INSTRUCTION MANUAL MARINE WATER HEATER WITH DUAL HEATING AS STANDARD ELECTRICAL HEATING AND INDIRECT HEATING ...

Page 2: ...210 0339_figure docx FIG_04 1 FIG_05 1 FIG_05 2 FIG_07 1 FIG_07 2 FIG_07 3 ...

Page 3: ...struction for use of the appliance by a person responsible for their safety Children being supervised not to play with the appliance Do not clean appliance parts with flammable fluids and do not store or use gasoline or other flammable vapors and liquids in the vicinity of this Gases and vapours can create a fire hazard or explosion The packaging material plastic bags foam clips etc Must be kept a...

Page 4: ...ferent energy from that of the hot fluid under pressure discharge a quantity of fluid such as to prevent them from being exceeded the predetermined pressure and temperature limits to protect the storage tanks Calibration 800 kpa 116 psi 8 Hot water outlet 10 Mounting bracket 6 GENERAL WARNINGS The installation must be performed in accordance with current legislation by a qualified person who can d...

Page 5: ...SIBLE DAMAGE CAUSED BY FAILURE OF THE APPLIANCE BE GROUNDED The apparatus is equipped with a power cord with plug Plug the power cord in accordance with the wiring regulations in force in the country where the equipment is installed Should it is not necessary to use the safety plug is possible to cut the power cord and connect it to a different plug or directly to the supply connection operation t...

Page 6: ...e water is discharged through the outlet of which is equipped with the valve A small amount of water may escape from this exhaust during the step of heating water CONTINUE A LOSS OF WATER FROM THE VALVE MAY INDICATE A PROBLEM WITH HEATING FAILURE TO OPERATE THE RELIEF VALVE EASING GEAR AT LEAST ONCE EVERY SIX MONTHS MAY RESULT IN THE WATER HEATER EXPLODING CONTINUOUS LEAKAGE OF WATER FROM THE VALV...

Page 7: ...210 0339_figure docx FIG_08 1 FIG_08 2 FIG_09 1 FIG_12 1 FIG_14 1 FIG_11 1 ...

Page 8: ...0 0334 edizione 2017 12 ATI DI MARIANI SRL Via E Mattei 461 Zona Ind Torre del Moro n 4 47522 Cesena FC ITALIA Tel int 39 0547 609711 Fax int 39 0547 609724 www nautica atimariani it nautica atimariani it ...

Reviews: