Athletica Sport Systems GlassFlex Manual Download Page 5

GlassFlex® adjustment

Product Manual

554 Parkside Drive, Waterloo, Ontario, Canada N2L 5Z4  TEL 519-747-1856

720 Innovation Drive, Shakopee, Minnesota, USA 55379  TEL 763-249-7465

Step 3: Adjusting U-Bolts and GlassFlex® Buffers to level shielding (cont’d)

Start to tighten the top nuts

 (fig. 5)

 through the access holes inside the aluminum tube. Tighten the two top nuts 

equally to ensure the bottom on the U-Bolt remains level. 
Repeat this for both U-Bolts supporting a single section of GlassFlex® channel until the shielding leans towards the 

ice surface

 (fig. 6)

.

Use a suction cup attached to the shielding and shake the shielding as you adjust the U-Bolt. This will help in 

making sure the shielding is level.
When you have completed the adjustments, use a level to ensure you are ‘level to 1/4” leaning over 3 feet’ towards 

the ice surface.

When the U-Bolt is in the desired position and level, raise the center nuts

 (fig. 7) 

under the tube until they are tight 

against the tube

 (fig. 8) 

and the U-Bolt is rigid.

fig. 5

fig. 6

fig. 7

fig. 8