Trouble Shooting for Steam Cabin
CAUSE
SOLUTION
TROUBLE
5.Thermal switch in the heater
is wrong
6.The heater is wrong.
7.The set temperature is lower
than room temperature.
Change thermal switch
installed inside the heater.
Change the heater.
Reset temperature.
Steam
generator
keeps adding
water.
1.The water inlet electro-
magnetic valve is wrong.
2.Water level sensor could not
detect signal.
Replace water inlet valve
Clean scale on water level
sensor or replace it.
Power supply is
off when on/off
button is pushed.
1.There is creepage from heater.
2.There is creepage from thermal
switch inside heater.
The seal is damaged.
Water leaks
from valve.
Water flow
volume is low.
Water supply has impurities
and jammed the filter net.
Replace heater.
Replace thermal switch.
Change the seal.
Get filter net cleaned.
No Steam
Romove the cover of cleaning liquid inlet
and input around 1L of citric acid or acetic
acid. Then start steam function to fill steam
generator with water. Stop steam function
before steam coming out (acid steam has
causticity to plated parts. If a lot of acid
steam come out, the plated parts become
cloudiness after some time.) Do not shut off
the control system and keep it on. The scale
in the steam generator dissolves in acid
liquid and the system drains the dirty water
out automatically after 60 minutes. Clean
the steam generator every 3 months.
Touch panel
does not work.
2.The control system is wrong.
No Steam
CAUSE
SOLUTION
Steam Generator Cleaning
Trouble Shooting for Steam Cabin
TROUBLE
1.Communication line is short
circuit or open circuit
.
Check connection between
control panel and power box.
Change control panel or power
box.
1.The water supply is shut off
.
Turn on the water supply valve.
2.No water supply in this area.
3.The water inlet valve cannot
be turned on.
4.The water level sensor is
wrong.
Use the product when water
supply is normal.
Check water inlet valve and
output signal from it.
Clean scale on water level
sensor or replace it.