5.4 SNMP interface
Object
OID
OID type
Description
MIB-2
(iso.org.dod.internet.mgmt.mib-2.sysem.x / .1.3.6.1.2.1.1.x)
sysDescr
.1.
DisplayString
Includes serial no.
sysUpTime
.3.
TimeTicks
Uptime of the network management
sysName
.5.
DisplayString
set in the web GUI
sysLocation
.6.
DisplayString
set in the web GUI
ATHENA-MIB A060-Mini
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.x / .1.3.6.1.4.1.36043.1.x)
A060-MiniLinkQuality
.1.
Integer
1: Green
2: Yellow
3: Red
A060-MiniReceivePower
.10.
Integer
Receive signal level [dBm]
A060-MiniTemperature
.11.
Integer
Temperature [˚C]
A060-MiniLocDetector
.12.
Integer
Lock detection signal level
A060-MiniifEthernetIn
.15.
Integer
Total frames received on the Ethernet interface over a
period of 10 seconds.
A060-MiniifEthernetOut
.16.
Integer
Total frames sent on the Ethernet interface over a
period of 10 seconds.
A060-MiniifEthernetError
.17.
Integer
Total frames dropped due to errors received on the
Ethernet interface over a period of 10 seconds
A060-MiniifAirIn
.18.
Integer
Total frames received on the Air interface over a period
of 10 seconds.
A060-MiniifAirOut
.19.
Integer
Total frames sent on the Air interface over a period of
10 seconds.
A060-MiniifAirInError
.20.
Integer
Total frames dropped due to errors received on the Air
interface over a period of 10 seconds.
A060-MiniFirmwareversion
.21.
String
Installed firmware version
ATHENA-MIB A060-Minitraps
(iso.org.dod.internet.private.enterprises.athenaminiOID.mini.miniTraps.x / .1.3.6.1.4.1.36043.1.22.x)
A060-MiniLinkQualityImprovedTrap
.1.
Integer
1: from red to green
2: from red to orange
3: from orange to green
A060-MinilinkQualityReducedTrap
.2.
Integer
1: from red to green
2: from red to orange
3: from orange to green
A060-MiniTemperatureHighTrap
.3.
Integer
A trap indicating that the temperature within the unit is
at or
above
70 degree Celcius
A060-MiniTemperatureLowTrap
.4.
Integer
A trap indicating that the temperature within the unit is
at or below -40 degree Celcius
Summary of Contents for A060-Mini
Page 1: ...Wireless Communications Installation and User Manual A060 Mini Revision B ...
Page 2: ......
Page 4: ...Wireless Communications ...
Page 22: ...Page 18 Wireless Communications A Map Of America ...
Page 23: ...Page 19 Wireless Communications B Map of Asia and Middle East ...
Page 24: ...Page 20 Wireless Communications C Map of Europe ...