background image

 

 

C

E

R

T I F I

E

D

M

A

N

AG

EMENT  SY

ST

E

M

et

N

Azienda Certificata 

UNI EN ISO 9001

 

A.D. VIGANO’ s.r.l. 

Via T. Tasso 50  
20049 Concorezzo (MI)  
Tel. 0039 - 039 - 61153.1 R.A.   Cap. Sociale £ 199.000.000 I.V. 
Fax 0039 – 039 – 6040695 

P.I. C.F. 02046450967 

E-mail:[email protected]   

R.E.A. NR. 1339422 

http://www.ad-vigano.com 

R.I.N. MI 149 - 44418 

 

Dichiarazione di conformità CE-015/1 

Declaration

 

of Conformity CE-015/1

 

 

 

 

In accordo alla 

in conformity to the

 EN 45014 

 
 

Questa dichiarazione si applica ai seguenti prodotti / 

This Declaration of Conformity is relevant to the following  products 

 
 

Proiettori Serie “ RLEQ . . . 

Floodlights Series “ RLEQ . . .  

 

 

 

 

Modo di protezione:  

 

 

 

Protection concept:

        I M2, EEx d I 163-191°C IP65

 

 
   ______________________________________________ 

 

 

 

 

 

 

 

 

conformi alle direttive europee       

94/9/EC

 

relevant european directive

  

89/336/EC

  

 

 

 

 

 

 

 

 

 
 

 

 

 

   standards 

armonizzati 

applicati

       EN 50014 : 1997 +A1/A2

 

applied harmonized standards

 

EN 50018 : 2000 +A1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Standards nazionali o documenti normativi applicati / 

applied national standards or normative documents 

 

EN 60598-2-5:1998 

 

EN 60529:1997 +A1   

 
 

Ente notificato / Notified Body: 

CESI 0722 

 

 

 

 

Notifica della produzione / 

EC Type Examination 

CESI 03 ATEX 019

 

Q

   

 

 

 
   _____________________________________________________________ 
 

 

 

 

 

 

   Technical 

File 

no.  

INERIS 06 ATEX 0001

 

   _____________________________________________________________ 
 
   Signature 

of 

manufacturer 

 

 
 
 
 
   function 

of 

the 

signer 

  Managing 

Director 

  

 

 

 

 

 

 

 

 

   Data 

Date: 

17/01/06 

 

 

Noi AD Viganò S.r.l. 

Italia 

dichiariamo sotto la 

nostra 

responsabilità che 

il prodotto menzionato 

è in accordo 

con le direttive europee 

applicabili ed agli 

standard armonizzati 

elencati e ai documenti 

normativi. 

Dove applicabile, 

un ente competente 

ha  rilasciato 

l'EC Tipo Esame 

attinente 

We, AD Viganò S.r.l. 

Italy 

declare under our sole 

responsibility that 

the mentioned

 

product 

is in accordance 

with the applicable 

european directive and 

to the listed harmonized 

standards or 

normative 

documents. 

Where applicable, 

a competent body 

has been released 

the relevant

 

EC Type 

Examination

 

Summary of Contents for RLEQ Series

Page 1: ...ons IS 014 1 Proiettori serie RLEQ IS 014 1 Floodlight series RLEQ Approvato Approved FF foglio 1 di 6 sheet 1 of 6 A D VIGANO s r l Via T Tasso 50 20049 Concorezzo MI Tel 0039 039 61153 1 R A Fax 0039 039 6040695 E mail info ad vigano com http www ad vigano com ATEX Instructions Floodlights series RLEQ I M2 EEx d I 163 C 191 C Test Certificate INERIS 06 ATEX 0001 Istruzioni ATEX Proiettori serie ...

Page 2: ... correct installation and connection Refer to the same for detailed instructions Usage Limitation The floodlight are manufactured in accordance to EEx d I 163 C 191 C protection The protection level covering every single box is indicated on the certification and rating Istruzioni per l uso ATEX Generalità Le misure di sicurezza e le apparecchiature utilizzate sul posto d installazione esercizio e ...

Page 3: ...nsability that the containers are manufactured at a state of art for what concerns safety and are in accordance to applicable CE Directives and that verifications and individual tests as required and indicated on the components certificates have been carried out with positive result Targa dati e marcatura ATEX Tutti i proiettori sono dotati di targhe indelebili e durevoli sono fissate lateralmente...

Page 4: ...h two hinges The body contains the lamp the diffuser and the electric equipments The cover is provided of temperate glass sealed with silicone for hight temperatures and of the steel guard The explosion proof is guaranteed from the sealing of the glass from the joint plain between body and cover that it provide the lamination of the flame The terminal block for the electric connection is set in ex...

Page 5: ...damenti Verifications and maintenance The verification and maintenance of the electrical equipments in places with explosion dangers must be performed following the instructions of EN 60079 17 rule Before any maintenance intervention which requires the opening of the enclosure to access the internal equipments power must be switched off for this the user will have to foresee inside a custody with ...

Page 6: ...le entries must be made using cable glands EEx d certified in accordance to the EN 50014 and EN 50018 rules The used cable has to have a use temperature greater or equal to 90 C The cable glands must be correctly choosen depending on the type of equipment and the cable type The cable glands must be duly tightened so that the sealing rings reach the necessary pressure a To avoid the transmission of...

Page 7: ...18 2000 A1 Standards nazionali o documenti normativi applicati applied national standards or normative documents EN 60598 2 5 1998 EN 60529 1997 A1 Ente notificato Notified Body CESI 0722 Notifica della produzione EC Type Examination CESI 03 ATEX 019 Q _____________________________________________________________ Technical File no INERIS 06 ATEX 0001 _______________________________________________...