MC
www.atestgaz.pl
10
Product marking
SmArtGas 4 Gas Detector
PW-044-SG4-
-
-
-
-
-
-
-
-
-
Converter module
X
Selected by the manufacturer depending on the chosen
– field value does not matter
when ordering the product (when ordering, please specify X, available EC, PEL, IR, PID options
show the used sensor type – see DOK-6073)
Display
Gas detector operating temperature with display can also be narrowed due to Ta
temperature limits due to Atex certificate – see table Technical specification.
0
Without
LCD
LCD display and LED controls
(Ta: -20 – 50°C)
Note: a decrease in contrast may occur at -20°C – difficult reading
FLED
Bright, multi-colour display
(Ta: -40 – 60°C)
FLED.A
Bright, multi-colour display equipped with an acoustic signaller
(Ta: -40 – 60°C)
Measuring head
Gas detector operating temperature with measuring head can also be narrowed due to
Ta temperature limits due to Atex certificate – see table Technical specification.
Type of the measuring head installed in the detector is associated with the
– the head specification is
determined by gas to be detected and its parameters
FL
With sinter (fast – reduced T90), made of stainless steel
FL.M
With sinter (fast – reduced T90) and membrane, made of stainless steel
FH
With sinter (fast – reduced T90), made of stainless steel, warmed
FH.M
With sinter (fast – reduced T90) and membrane, made of stainless steel, warmed
HL
With sinter, made of stainless steel
HH
With sinter, made of stainless steel, warmed
Enclosure
ALB
Aluminium, spray epoxy – white
ALZ
Aluminium, spray epoxy – yellow
(the version is available only for authorized distributors)
SS
Stainless steel
C
Aluminium, creodur coating – natural aluminium
Temperature
0
Standard
(Ta: -30 – 50°C)
T
Extended temperature range for gas detector
(Ta: -40 – 85°C)
Digital interface
485
RS-485
Teta
Teta Bus –
under development
Analog interface
0-0
Without
420-PK
4 – 20 mA (sink/source) + 3 x relay
Wireless interface
0
Without
BT
Wireless interface allowing remote sensor calibration – under development
Measurement parameters
configuration
-
See details and
Ta
in DOK-6073 „Measurement parameters configuration”
Cable gland
0
Without
X
See details in POD-066-ENG „Cable glands used in gas detectors produced by Atest Gaz”
Table 14: Method of product's marking
p