*Stroke (measuring) 

length 

Different measuring lengths from 400 
mm to 3000 mm 

Required Force 

5 N 

Linearity 

±0.25% FS 

Operating 

Temperature

 

-25°C … +85°C 

*Supply Voltage 

‘A‘ and ‘V’ models: 24 VDC 

Potentiometric output model: 42V max. 

Relative Humidity 

 %95 

*Signal Output Type 

Potentiometric 
0-10 VDC  
4-20 mA 

Materials 

Housing: Aluminum/steel /ABS 
plastic 
Measuring Wire: Stainless steel  
(0.5mm or 1mm) 

Measuring Type 

Potentiometric 

*Connection cable 

length

 

3m (standard), 5m, 10m 

*Resistance 

5 KΩ (standard), 10 KΩ 

IP Protection Class 

IP65 

Maximum Speed 

2 m/s 

Weight 

≈550 gr  

Note:

 The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.

 

 

 

 

 

MECHANICAL MOUNTING 

 

1- The product should be mounted to the relevant area with 2 units 
M4 bolts(1) and nuts(2) from the mounting rails (3) according to the 
mounting directions shown on page 3. 
 
2- The sensor wire should be pulled towards the position to be 
connected with the barrel bolt (5).

 

 
3- The sensor wire should be mounted on the device to be connected 
by using the setting nut (4). 
 

DIMENSIONS 

 

TECHNICAL SPECIFICATIONS 

 

Summary of Contents for AWP 120 Series

Page 1: ...tween the sensor and control unit Avoid additions except the suitable connector unless it needs Keep away the sensor cable from as high power energy cables contactor motor switched power supplies inductive and capacitive noisy supplies Shielding edge of the sensor cable must be ground connected Not to damage the sensor supply directions and voltage must be paid attention Don t energize before all ...

Page 2: ...e length 3m standard 5m 10m Resistance 5 KΩ standard 10 KΩ IP Protection Class IP65 Maximum Speed 2 m s Weight 550 gr Note The technical specifications indicated by vary according to the selected model The detailed code table is shown on page 4 MECHANICAL MOUNTING 1 The product should be mounted to the relevant area with 2 units M4 bolts 1 and nuts 2 from the mounting rails 3 according to the moun...

Page 3: ... not be pulled in angular If needed please use guide rollers 1 Never release the wire after pulling Otherwise the coil spring will be damaged Guide Roller Guide Roller Important Note Failure to comply with these recommendations the malfunctions that may occur will not be under the warranty MOUNTING AND USAGE WARNINGS Guide Roller Product Description AWP 120 Draw Wire Sensor Mounting Equipment 4 pc...

Page 4: ...trical Connection 3 3M 3 m 5M 5 m 10M 10 m S13 M12 5 pin male socket Manufacturer Firm s Title Address Details Manufacturer Firm ATEK SENSÖR SANAYİ VE TİCARET A Ş Address Tuzla KOSB Organize Sanayi Bolgesi Melek Aras Bulvari No 67 34956 Tuzla Istanbul TURKEY TEL 90 0216 399 44 04 FAX 90 0216 399 44 02 Web www ateksensor com E mail info ateksensor com Authorized Service s Title Address Details Auth...

Page 5: ...SP Brazil Brasil Phone Telefone 55 16 3371 0112 55 16 3372 7800 Internet www metrolog net metrolog metrolog net Metrolog Controles de Medição Atek Sensor Technology A S Tuzla Kimya Sanayicileri Org San Bolg Melek Aras Bulvari No 67 34956 Tuzla Istanbul TURKEY Tel 90 216 399 44 04 Fax 90 216 399 44 02 www ateksensor com info ateksensor com ...