KK-AWP.001 23.06.21 Rev No:3
2
*Stroke (measuring)
length
Different measuring lengths from 200
mm to 1200 mm
Required Force
5 N
Linearity
±
0.25% FS
Operating Temperature
-
25°C … +85°C
*Supply Voltage
‘A‘
and
‘V’ model
s:
12…30 VDC
Potentiometric output model: 42V max.
Relative Humidity
%95
*Signal Output Type
Potentiometric
0-10 VDC
4-20 mA
Materials
Housing: Aluminum/steel /
plastic
Measuring Wire: Stainless steel
Measuring Type
Potentiometric
*Connection cable
length
3m (standard), 5m, 10m
*Resistance
5 KΩ (standard), 10 KΩ
IP Protection Class
IP53 (optional IP67)
Maximum Speed
2 m/s
Weight
≈550 gr
Note:
The technical specifications indicated by (*) vary according to the selected model. The detailed code table is shown on page 4.
MECHANICAL MOUNTING
1- The product should be mounted to the relevant area with 2 units
M4 bolts(1) and nuts(5) from the mounting holes (2) according to the
mounting directions shown on page 3.
2- The sensor wire should be pulled towards the position to be
connected with the barrel bolt (4).
3- The sensor wire should be mounted on the device to be connected
by using the setting nut (3).
DIMENSIONS