Atek AWP 110 Series User Manual Download Page 1

KK-AWP.001 23.06.21 Rev No:3 

 
 
 
 
 
 
 
 

 
 
 
 
 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

AWP 110 

      

 

DRAW WIRE SENSOR USER MANUAL 

Never make or undo electrical connections to the sensor when voltage is applied, otherwise this may result in damage to 
devices. 
 

M12 5 Pin Male Socket 

 

The  installation  of  the  product  is  carried  out  by  the  customer  who  purchases  the  product,  according  to  the  wiring  diagrams, 
installation information, etc. in this manual. 

 

Maintenance and repair should be done by the technicians authorized by the manufacturer firm. 

 

There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless it 
needs. 

 

Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and capacitive 
noisy supplies. 

 

Shielding edge of the sensor cable must be ground connected. 

 

Not to damage the sensor, supply directions and voltage must be paid attention. 

Don’t energize before all conne

ctions completed. 

 

Transport and storage should be at their original packaging and an ambient temperature of  -

25°C / + 85°C in such a way that they 

will not be exposed to dust, humudity, impact, vibration, falling or water. 

 

Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a damp 
cloth. 

 

The product may be damaged and may become unusable if used outside of the specifications in the user manual. 

 

The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other 
than authorized services. 

 

 
 

AWP  110  series  draw  wire  sensors;  consists  of  a  rotary  potentiometer  which  is 
controled  by  stainless  steel  wire.  They  make  measurement  by  pulling  and  rewinding 
stainless steel wire.  
Different  measuring  lengths  from  200  mm  to  1200  mm  are  available.  They  converts 
linear motion to potentiometric output. 

The “A” series, works with 24VDC supply and gives of 4

-20 mA analog output with the 

help of the converter card. 

The “V” series, works with 24VDC supply and gives of 0

-10 VDC analog output with the 

help of the converter card. 
Optionally,  different  non-standard  measuring  lengths,  cable  length  or  socket  model 
can be requested. 
 

WARNINGS 

 

GENERAL INFORMATION 

 

 

ELECTRICAL CONNECTIONS 

 

4-20 mA Connection 

Signal 

Cable Color 

M12 5 pin male socket 

Earth 

Silver 

Pin 1 

+V 

Red 

Pin 2 

Pin 3 

4-20 mA 

Yellow 

Pin 4 

Pin 5 

 

0-10V or POTENTIOMETER Connection 

Signal 

Cable Color 

M12 5 pin male socket 

Earth 

Silver 

Pin 1 

+V 

Red 

Pin 2 

0V 

 

Black 

Pin 3 

0-10V / Pot 

Yellow 

Pin 4 

Pin 5 

 

Summary of Contents for AWP 110 Series

Page 1: ...ter Chemicals such as alcohol thinner etc should not be used for cleaning the product The product should be wiped with a damp cloth The product may be damaged and may become unusable if used outside of the specifications in the user manual The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other than authorized services AWP 110 serie...

Page 2: ...andard 5m 10m Resistance 5 KΩ standard 10 KΩ IP Protection Class IP53 optional IP67 Maximum Speed 2 m s Weight 550 gr Note The technical specifications indicated by vary according to the selected model The detailed code table is shown on page 4 MECHANICAL MOUNTING 1 The product should be mounted to the relevant area with 2 units M4 bolts 1 and nuts 5 from the mounting holes 2 according to the moun...

Page 3: ...hould not be pulled in angular If needed please use guide rollers 1 Never release the wire after pulling Otherwise the coil spring will be damaged Guide Roller Guide Roller Important Note Failure to comply with these recommendations the malfunctions that may occur will not be under the warranty Product Description AWP 110 Draw Wire Sensor Mounting Equipment 2 pcs M4 bolts and nuts User Manual 1 pc...

Page 4: ... recycling facilities Disposal of E Waste This device is in conformity with WEEE Directive and consists of recyclable materials This product should not be disposed with general waste for preventing negative effects on enviroment and human health This product should be disposed to collecting points of authorized recycling facilities Further information can be reached from authorized unit Manufactur...

Reviews: