Product Features
59
© 2017, ATEÏS, member of PAX ProAV Group
example: On the PDC port, you can connect 32 PPM-AS through junction boxes and are able to
assign IDs in sequence for each unit in Ateis Studio.
When connecting to both Fireman Mic and other remote units, the priority status of Fireman Mic
shall be higher than any other microphone remote units lining to PDC port.
If a large number of remote units is required, simply add more slave units for the master unit.
Eth. Limit: The maximum number of IP that can be assigned over the network.
3.1.5.5
3rd Party Control
The following table lists the 3rd Party Control protocols supported by IDA8C-SW.
Protocol
Interface
Function
Connection
Settings
Ateis 3rd Party
Protocol
Ethernet(UDP) UDP Port = 19761
Read/Write value of parameters.
Stepped adjustment for parameters.
Telephone card function
Modbus
Ethernet(TCP)
PDC(RS485)
TCP Port = 502
PDC Port 1~ 4
Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control
3.1.6
IDA8SAB-SW
IDA8SAB (Switch Mode) provides the zones and audio in & out expansion using a secured 48-channel
audio and data network over CAT5 or fiber optic. IDA8SAB (Switch Mode) requires less number of