IDA8 Global-Net User Manual
126
© 2017, ATEÏS, member of PAX ProAV Group
provide users with a multi-functional combination for preference.
In case you might face any common issue of how these three types work, please see
chapter.
6. Select as a backup Amplifier(This function shall only be displayed and adjusted under the use of
economic mode).
Normal Use: Select to enable the backup amplifier as Voice or Music sources simultaneously
when the backup amplifier is vacant currently.
3.1.10.3 Procedure of Monitoring Setup
The connection wiring of hardware has completed before the monitoring setup, as the IDA8C/S will get
the values from the hardware's initial state for reference. When the system is operating and reference
values are correctly achieved, the IDA8C/S continuously measures the internal status and compares it
with referenced values to determine if there are incorrect processes of zone/amplifiers.
1. Setup hardware equipment, including an IDA8C/S, a normal amplifier, a backup amplifier,
speakers and wiring between the devices,
2. Create a configuration using Ateis Studio.
3. Store the configuration, then online.
4. Set appropriate settings for your application on Ateis Studio. You can see more details on the
following topic
5. Press [Get reference] button to start the monitoring for the zone you selected.
3.1.10.4 Redundancy Switching Faults
The below errors will result in redundancy switching.
All the
will result in redundancy switching.
All the faults under the selected the checkbox on [Bypass] mode will result in redundancy
switching.