background image

16

© 2018, ATEÏS, member of PAX ProAV Group

8

Contact information

www.ateis.com

 ATEÏS Europe B.V. 

 EMEA 

 Penton Audio USA 

 USA, Canada & Latin America 

Celsiusstraat 1 - 2652 XN Lansingerland

 (Rotterdam Region), Netherlands

Tel: +31 (0) 10 2088690

[email protected]

21 Sabin St. Pawtucket,

RI 02860, USA

Tel: 401-727-1600

Fax: 401-727-0003

[email protected]

 

 ATEÏS France 

 ATEÏS China 

8, rue de l'Europe - 

ZA de Font Ratel,

38640 Claix, France

Tel: 33 (0) 4 76 99 26 30

[email protected]

Room 610, No. 255 Wubao Road,

Minxing district, Shanghai, China

Tel: 021-54495191/92

Fax: 021-54495193

[email protected]

 Penton UK Ltd. 

 UK & Ireland 

 Xavtel Communications RUS Ltd. 

 Russia 

Unit 2, Teville Industrials, Dominion Way,

Worthing West Sussex,

BN14 8NW, United Kingdom

Tel: +44 (0)1903 215315

Fax: +44 (0)1903 215415

[email protected]

Russian Federation, 115280, Moscow

Leninskaya Sloboda str., 26 bld. 28, Business

Center "Slobodskoy", office #122

Tel: +7 495 803 3655

Fax: +7 495 803 3655

[email protected]

 ATEÏS Far East CORP. 

 Far-East Asia 

 ATEÏS Suisse SA 

 Switzerland & South-East Europe 

No.60, Xinghua 2nd Rd, Tanzi, 

Taichung 427, Taiwan
Tel: +886-4-25333820

Fax: +886-4-25333830

[email protected]

Avenue des Baumettes 9, 

1020 Renens VD, Switzerland

Tel: +41 (0) 21 881 25 10

Fax: +41 (0) 21 881 25 09

[email protected]

 ATEÏS Middle East 

 ATEÏS SE PTE Ltd. 

 South-East Asia 

Light Industrial Unit 11 Dubai 

Silicon Oasis, Dubai United Arab Emirates

Tel: +971 4 3262730

Fax: +971 4 3262731

[email protected]

Blk 5002 Ang Mo Kio Avenue 5, #03-01B

TECHplace II. Singapore 569871

Tel: +65 6481 1968

Fax: +65 6481 1960

[email protected]

Summary of Contents for DPA2500

Page 1: ...MODEL 2018 ATEÏS member of PAX ProAV Group User Manual Revision History v1 07 DIGITAL POWER AMPLIFIER DPA8060 DPA4125 DPA4250 DPA2500 ...

Page 2: ...mplifier 5 5 2 1 2 1 Front panel 6 2 2 2 2 Rear panel 3 Hardware installation 8 8 3 1 3 1 Mounting 8 3 2 3 2 Connect to AC mains power 8 3 3 3 3 Connect to battery charger power sharing 9 3 4 3 4 Audio input audio output 9 3 5 3 5 Bridged output 4 Maintenance 11 5 Troubleshooting 12 6 Technical data 13 7 Standard and certification 15 8 Contact information 16 ...

Page 3: ...nect the power cord only to an AC outlet of the type stated in this manual or as marked on the unit Otherwise fire and electrical shock hazard results When disconnecting the power cord from an AC outlet always grab the plug Never pull the cord A damaged power cord is a potential risk of fire and electrical shock hazard Avoid touching power plugs with wet hands Doing so is a potential electrical sh...

Page 4: ...hazard To prevent the unit from falling down and causing personal injury and or property damage avoid installing or mounting the unit in unstable locations Leave enough space above and below the unit to provide good ventilation of the device If the airflow is not adequate the device will heat up inside and may cause a fire Operate the device in an environment with a free air temperature of between...

Page 5: ...verload and signal on the front panel and the DPA models can bridge two channels to double the power wattage 2 1 Front panel The front panel of DPA2500 DPA4125 DPA4250 DPA8060 is identical except the number of channel is different 1 Power LED This LED lights up if the DPA is powered by AC mains power 2 Battery LED This LED lights up if the DPA is powered by 48VDC power supply 3 GEN fault LED This ...

Page 6: ...hausts it from the rear panel Please make sure that these inlet holes are not obstructed 2 2 Rear panel DPA2500 DPA4125 DPA4250 DPA8060 The rear panel of DPA2500 DPA4125 DPA4250 DPA8060 is identical except the number of channel is different and the DPA8060 does not have Lamp input and Spare contact input 1 AC mains power socket Connect the mains AC power to this power socket 100 VAC 240 VAC 50 60 ...

Page 7: ...is malfunction 4 Spare contact input DPA2500 4125 4250 Reserved for further usage 5 Channel 1 8 output Each channel delivers 60W DPA8060 125W DPA4125 250W DPA4250 500W DPA2500 and both EU and US types are available as different models EU type 100V 50V 4 ohm US type 70V 35V 4 ohm 6 Channel 1 8 inputs volume gain There is a balanced terminal and a gain control for each input channel 7 48VDC battery ...

Page 8: ... heat generating devices like power supplies or power amplifiers 3 2 Connect to AC mains power 1 The DPA has a 100 VAC 240 VAC mains power supply please make sure the voltage is applicable for your country s main voltage 2 Connect the power cord to the DPA and plug it into the mains outlet 3 3 Connect to battery charger power sharing The connection diagram below is using the BOUTIQUE system for ex...

Page 9: ...ection of amplifier output on DPA is varies with EU 100V 50V 4 ohm and US types 70V 35V 4 ohm 3 Connect and loudspeakers on BTQ VM8 controller 3 5 Bridged output Bridge the two channels of DPA amplifier such as 500W x 2 CH DPA2500 to 1000W x 1 CH or bridge each two channel of DPA8060 60W x 8 CH to 120W x 4 CH Please see the instruction as below 1 Connect an audio input on Channel 1 2 Bridge the au...

Page 10: ...10 2018 ATEÏS member of PAX ProAV Group 4 Set the volume of gain knob on Channel 1 to the maximum volume ...

Page 11: ...ir jet between the fins of the heat sinks User maintenance User maintenance should be done by qualified personnel only Dangerous mains voltages are present inside the units Unplug the main power supply before you do any maintenance Users can inspect if any broken connectors ground cable connections or loose screws on the outside of amplifier If any loose parts rattle around on the inside when the ...

Page 12: ...ccurred See Technical Data Loudspeakers Outputs 2 Disconnect the speakers and check if the output is short 3 Check if the Service Request Contact output is open If yes the hardware is damaged broken AC power fault Battery power fault 1 Check the voltage is under the normal range AC mains 100 240VAC Battery supply 43 56VDC 2 Check if the Service Request Contact output is open If yes the hardware is...

Page 13: ...70V 35V 4 ohm EU type 100V 50V 4 ohm Audio characteristics Frequency response 50 Hz 20 kHz 3 dB 0 dBu SNR 90 dB THD N 0 1 1 kHz Max input level 0 dBu Input impedance DPA2500 10K ohm DPA8060 DPA4125 DPA4250 12K ohm Crosstalk 70 dB 0 dBu gain Loudspeakers outputs 1 min at 40 C per CH Model Rated output power Rated load resistance DPA8060 60W 167 ohm 100V 82 ohm 70V 41 6 ohm 50V 20 ohm 35V DPA4125 12...

Page 14: ...x 15 2 inch DPA2500 437 x 88 x 387 mm 17 2 x 3 5 x 15 2 inch DPA4250 14 5 kg 32 lbs DPA2500 16 kg 35 2 lbs Mounting 19 2U rack Color RAL 7016 Environmental Operating temperature 5 ºC 55 ºC 23 ºF 131 ºF Storage temperature 40 ºC 70 ºC 40 ºF 158 ºF Relative humidity 20 to 95 Air pressure 600 to 1100 hPa Heat dissipation DPA8060 767 BTU hr DPA4125 512 BTU hr DPA4250 1024 BTU hr DPA2500 1092 BTU hr ...

Page 15: ...m is approved processing pending and complied to the following Europe Voice Alarm EN54 16 in process Europe CE EMI EN55032 2015 AC 2016 Class A Europe CE EMC EN61000 3 2 2014 EN61000 3 3 2013 EN55020 2007 A11 2011 Europe CE LVD EN60065 2014 in process USA Mass Notification Systems UL2572 pending USA Safety UL60065 pending ...

Page 16: ...nion Way Worthing West Sussex BN14 8NW United Kingdom Tel 44 0 1903 215315 Fax 44 0 1903 215415 sales pentonuk co uk Russian Federation 115280 Moscow Leninskaya Sloboda str 26 bld 28 Business Center Slobodskoy office 122 Tel 7 495 803 3655 Fax 7 495 803 3655 info xavtel ru com ATEÏS Far East CORP Far East Asia ATEÏS Suisse SA Switzerland South East Europe No 60 Xinghua 2nd Rd Tanzi Taichung 427 Ta...

Reviews: