Datenblatt

Digitale Temperaturanzeige CUB5TC

CUB5TC

Setpoint 

 

Action

Setpoint

 

Select

Setpoint

 

Value

Output Reset

 

Action

Hysteresis 

Value

Off Time

 

Delay

On Time

 

Delay

Output Reset

 

With Display

 

Reset

Change Display 

Color with  Output Stat

e

Backlight  Unit Only

SPSE

L

4-SPt

Act-n

SPt-n

HYS-n

tON-n

tOF-n

rSt-n

rEn-n

ChC-

n

Standby

 

Operatio

n

Stb-

n

brn-

n

Probe  Burn-out Actio

n

Front Panel  Reset Enable

Front Panel 

Display 

Select Enable

Display 

Update Time

dSP-t

SEL

rSt

3-dSP

Display  Intensity  Level

COLOr

Display  Scroll  Enable

ScroL

Display  Color

d-LEV

Backlight Unit Only

Programming  Security Code

CodE

Display 

Decimal Point

Thermocouple 

Type

tYPE

Cold Junction Compensation

CJC

1-INP

Temperature 

Scale

SCALE

dECPt

USrIN

User Input  Function

Filter Setting

Display Offset 

Value

OFSEt

FILtr

Filter Band

bANd

U-ASN

User Input  Assignment

LO-En

Min Display 

Enable

Max Capture  Delay Time

Max Display 

Enable

HI-En

HI-t

2-SEC

Min Capture  Delay TIme

LO-t

Factory  Service  Operations

FCS

Access Code

 

For Service

 

Operation

s

CodE

PAr

Parity Bi

t

Baud Rat

e

bAUd

Data Bi

t

dAtA

5-SEr

Meter  Address

Addr

Abbreviated 

Printing

Abbr

Print  Option

s

OPt

SEL

RS

T

 

 

NO 

 

 

Pro

Exit 

Programming

 

End

SEL

RS

T

RS

T

RS

T

RS

T

RS

T

SEL

SEL

SEL

SEL

cuB5tc proGraMMinG QuicK overvieW

Press and hold 

SEL

 button 

to enter Programming

 Mode.

Erstellt am 04.09.2021 um 05:30 Uhr | Alle Angaben ohne Gewähr, Irrtümer und Änderungen vorbehalten!

Seite 14 von 14

Summary of Contents for CUB5TC

Page 1: ...rsorgung frontseitig über Tastatur oder Software frontseitig über Tastatur Bedienung optional Relaisausgangskarte optional Transistorausgangskarte Schaltausgang Analogausgang 5 Anzahl Zeichen LCD Anzeige Thermoelement Eingang 75 x 38 mm Format Temperatur Art Thermoelement siehe Datenblatt Messbereich horizontal Ausrichtung 9 28 VDC optional externes Netzteil 85 250 VAC Ausgang 12 VDC 400 mA Versor...

Page 2: ...latt Digitale Temperaturanzeige CUB5TC CUB5TC IP65 frontseitig Schutzgrad 35 C 75 C Umgebungstemperatur RS232 optional RS485 optional Schnittstellenausgang Einbaugehäuse Bauart Digitalanzeige Ausführung Erstellt am 04 09 2021 um 05 30 Uhr Alle Angaben ohne Gewähr Irrtümer und Änderungen vorbehalten Seite 2 von 14 ...

Page 3: ...ature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use this meter to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially har...

Page 4: ...s Wire Strip Length 0 3 7 5 mm Wire Gage 30 14 AWG copper wire Torque 3 5 inch lbs 0 395 N m max 10 ENVIRONMENTAL CONDITIONS Operating Temperature Range for CUB5TCR0 35 to 75 C Operating Temperature Range for CUB5TCB0 depends on display color and intensity level as per below INTENSITY LEVEL TEMPERATURE Red Display 1 2 35 to 75 C 3 35 to 70 C 4 35 to 60 C 5 35 to 50 C Green Display 1 2 35 to 75 C 3...

Page 5: ... parity USB PROGRAMMING CARD Type USB virtual comms port Connection Type B Baud Rate 300 to 38 4k Unit Address 0 to 99 Optional Plug in Cards 1 0 Installing the Meter INSTALLATION The meter meets NEMA 4X IP65 requirements when properly installed The unit is intended to be mounted into an enclosed panel Prepare the panel cutout to the dimensions shown Remove the panel latch from the unit Slide the ...

Page 6: ... control cables is effective The following EMI suppression devices or equivalent are recommended Fair Rite part number 0443167251 RLC part number FCOR0000 Line Filters for input power cables Schaffner FN2010 1 07 Red Lion Controls LFIL0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally in...

Page 7: ...from user input common In order to preserve the safety of the meter application the power input common and the sensor input common must be suitably isolated from hazardous live earth referenced voltages or input common must be at protective earth ground potential If not hazardous live voltage may be present at the User Inputs and User Input Common terminals Appropriate considerations must then be ...

Page 8: ...any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module 1 and proceed through each module in sequence When programming is complete it is recommended to record the parameter programming and lock out parameter programming with the u...

Page 9: ...ELECTION TC TYPE TC TYPE SELECTION VOLt tc n N K tc b tc S tc K B S J tc j E tc E T tc t 0 OFSEt DISPLAY OFFSET VALUE The temperature display can be corrected with an offset value This can be used to compensate for probe errors errors due to variances in probe placement or adjusting the readout to a reference thermometer 999 to 9999 This parameter enables or disables internal cold junction compens...

Page 10: ... button for 2 seconds Unit will display CAL NO 3 Press the RST button to select INP 4 Press the SEL button Display reads 0 0u 5 With the voltage source set to zero press SEL Display reads CALC for about eight seconds 6 When display reads 60 0u apply 60 000 mV input signal Press SEL Display reads CALC for about eight seconds 7 When display reads CAL NO press SEL twice to exit Module 2 and return to...

Page 11: ... Not Active 0 999 Full Programming Immediate Access Entering Code 222 allows access regardless of security code 5 3 MODULE 3 Display and Front Panel Button Parameters 3 dSP SEL Pro Front Panel Display Select Enable Display Update Time Front Panel Reset Enable Programming Security Code Display Scroll Enable Display Color Backlight Unit Only 3 dSP dSP t SEL rSt ScroL COLOr CodE Display Intensity Lev...

Page 12: ...ER POINTS Low Acting Balanced Hys LO bL OUTPUT STATE OFF ON Hys SP SP Hys OFF TRIGGER POINTS High Acting Unbalanced Hys HI Ub 2 HYS n HYSTERESIS VALUE 1 to 59999 Enter desired hysteresis value See Setpoint Output Figures for visual explanation of how setpoint output actions balanced and unbalanced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is u...

Page 13: ... cycle When the user input or RST button is activated momentary action the meter delays the event until the corresponding on output crosses the trigger off point Previously latched outputs are off if power up Display Value is lower than setpoint value During a power cycle the meter erases a previous L dLY reset if it is not activated at power up OUTPUT STATE OFF ON Hys SP Auto OFF ON OFF OFF ON OF...

Page 14: ...Only Programming Security Code CodE Display Decimal Point Thermocouple Type tYPE Cold Junction Compensation CJC 1 INP Temperature Scale SCALE dECPt USrIN User Input Function Filter Setting Display Offset Value OFSEt FILtr Filter Band bANd U ASN User Input Assignment LO En Min Display Enable Max Capture Delay Time Max Display Enable HI En HI t 2 SEC Min Capture Delay TIme LO t Factory Service Opera...

Reviews: