Out of Vehicle Test
BATTERY TEST:
1.
Connect the B600 Local Transmitter to the battery to be tested. The green
Ready
LED and the yellow
Activity
LED will blink.
Note: make sure battery clips make contact with the lead battery post.
2.
Press the MENU ON/OFF button to turn on the remote.
“Techno Tools B600”
will appear momentarily on the
display and then the display will show
WAITING TO CONNECT.
W hen connected, the green LED will stop
blinking and display will show
IN VEHICLE TEST? PRESS NO (+)
.
3.
The display will then prompt the user to
SELECT BATTERY VOLTAGE
. Press the
+ UP
or
- Down
buttons to
select the battery or battery pack voltage i.e. 6V, 12V, 24V to be tested.
NOTE
: The maximum battery pack voltage for testing is 24V (2-12V batteries in series).
4.
Press
ENTER
←: The display will show the battery’s State of Charge (SOC) and display
GOOD, LOW, BAD
CELL REPLACE or SURFACE CHARGE
*.
5.
Press
NEXT +:
The display will prompt the user
TEST BATTERY.
6.
Press
ENTER
←:
The display will prompt the use to select the units of the battery rating:
CCA/SAE, EN, DIN,
EIC or JIS.
Press
+ UP
or
- DOWN
to select desired units.
7.
Press
ENTER
←: The display will prompt the user to select the rated battery size. Press the +
UP
or
- DOWN
buttons to select the battery’s numerical rating i.e. 550 CCA.
8.
Press
ENTER
←: The display will show
TESTING…….PLEASE WAIT
for a few seconds. The display will then
show the % available capacity** and the battery condition as
GOOD, MARGINAL
***
REPLACE, RECHARGE &
RETEST or BAD CELL-REPLACE.
*Removing the surface charge may improve the test accuracy when testing
MARGINAL
batteries. To remove surface
charge, load the battery for several seconds unit until the
SOC
voltage drops to 12.8V or less.
**If available capacity is 800 CCA’s or greater the Tester will prompt the user if the battery is an AGM type battery.
***For
MARGINAL
batteries the ATD5493 will prompt the user “
TEMPERATURE ABOVE 32°F
?”
Group 31 female
Stud adapters
Side- mount male
post adaters
base
2
PRIOR TO TESTING
Important:
Use stud or post adapters (provided with the ATD5493) when connecting to side mount or Group 31 batteries
outside of the vehicle. Or connect battery clips on the base of threaded stud when testing (see Fig. below). Make sure
adapters are properly tightened. Connecting the tester directly to threaded studs or bolts will result in false readings. When
connecting to batteries inside or outside of the vehicle, rock the clips back and forth to ensure a good connection.
CHECK
CONNECTION
may show on the display if a poor connection is detected. Reset clips if necessary.
UTILITY MENU OPTIONS
The utility menu allows the user to set up the
Language, Date & Time, Company Name, address, and phone #
. To enter
the Utility Menu: press
MENU
and
HOLD DOWN
the
NEXT +
button.
Setting up the Language:
The B600 will default to English. Press
NEXT +
to select the desired language and then press
ENTER
.
Setting up the Date and Time:
Press
NEXT +.
The display will show
Date Time Setup
. Press
ENTER
. The flashing cursor will blink over day
month year format (dd/mm/yy). Scroll up or down to select the desired number.
Setting up the Company Name, address & phone #:
Press
NEXT +
to set up the Company Name. Scroll the alphabet letters until the first letter of the company is
displayed. Press
ENTER
and proceed until the complete name address & phone # is displayed. Note: “Space” and
“Apostrophe” characters are shown at the beginning or end of the alphabet.