Maintenance 

 
 
 

 
 
 
 

 
 
 
 

Filter 

Keyway alignment

Pull straight out (do not 

twist)

to remove

sensor

Unscrew tip to 

replace filter 

Push straight on (do not 

twist) 

to install

 sensor 

Batteries: 

 

Install Batteries

: Remove screw located at rear end of unit and

pull down hinged battery door to open as shown.  Insert positive
battery (+) end towards the front of the battery compartment  

 

Sensor: 

 

Replace Filter

: Unscrew sensor tip as shown to replace filter.

Replace filter whenever it becomes visibly dirty or every 2 to 3
months depending on use. 
 

Replace Sensor

: Remove sensor by pulling out of socket. Install

the new sensor by aligning the notch in sensor cover with the raised
keyway on sensor socket holder (see figure below).  

 
Note: Do not force sensor into socket.  Misalignment can
damage the sensor pins. 

 

ATD-3700

Operating Instructions 

 

1. 

TURN ON:

 Press the ON/OFF button once to turn on and again 

to turn off. 

 
2. 

WARM UP

:  The detector automatically starts heating the 

sensor.  During the heating cycle, the digital leak size indicator 
will flash 8 and the detector will sound a slow “beep”.   Warm up 
is usually less than 20 seconds. 

 
3. 

READY

:  The detector is ready to begin searching for leaks 

when the flashing 8 stops and the green sensitivity LED turns on.  
The audio “beep” increases in frequency and probe LED begins 
to blink steadily. 

 
 

 
 

ATD-3700 Control Panel 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Digital Leak Size 

Indicator 

Low Battery 

Indicator

Sensitivity Level 

Audio Mute & 

Sensitivity Level 

Power 

  On/Off 

Reviews: