ATD Tools ATD-10535 Owner'S Manual Download Page 3

IMMEDIATELY SWITCH OFF THE TOOL IF THE FOLLOWING CONDITIONS EXIST: 

• Excessive sparking of the carbon brushes in the collector. 

• Interruption in the main power, main lead or main lead damage. 

• Switch is faulty. 

• Smoke or smell of scorched or burnt insulation. 

 

ELECTRICAL SAFETY 

Always check that the power supply corresponds to the voltage on the rating plate.   

 

Your tool is double insulated in accordance with EN 50144; therefore no ground wire is required. When replacing cable or plug, 

immediately throw away old cables or plugs. It is dangerous to insert the plug of a loose cable in the wall outlet. When using extension 

cables only use an approved extension cable suitable for the power input of the tool. When using a cable reel always unwind the reel 

completely. 

 

OPERATION 

CHANGING/FITTING THE BLADE 

 

• Be sure the tool is unplugged. 

• Loosen the blade lock screw with the 4mm hexagon key. 

• Insert the saw blade between the stroke rod and the clamping plate. 

• Take care that the securing pin of the stroke rod engages in the hole of the saw blade. (Saw blade cannot be pulled out). 

• Retighten the blade lock screw. 

• When changing the saw blade, make sure that the blade holder is free of material residue (e.g. wood or metal shavings), 

• Before plugging the saw into the wall outlet, double check to be sure the saw blade is secure. 

 

 

Make sure that the saw blade does not rest on or touch any objects when the tool is switched on. 

Switching on 

• Pull the on-off trigger switch (4). 

 

Switching off 

• Release the on-off trigger switch. 

• The on-off trigger switch can be locked on for continuous operation by pressing the trigger lock button while pulling the trigger. 

• To release the trigger lock, simply pull the trigger switch again. 

 

SPEED CONTROL 

• During operation and while the tool is at rest the stroke rate (speed) can be selected using the thumbwheel (5). The stroke rate will 

remain constant even under load. 

• The stroke rate required depends upon the material conditions. The optimal setting should be determined in use. 

• After working for longer periods at low speed you should allow the tool to cool down by running it at maximum speed with no-load for 

approx. 3 minutes.   