11.
Avoid the use of extension cords with this product, extension cords may
overheat and there could be a risk of fire.
12.
Do not make any modification to the Heater.
13.
Keep connections dry.
14.
If the power supply cord is damaged, do not use the heater until the cord has
been replaced. For power cord replacement, always contact an electrician in
order to avoid any risk of injury.
15.
If the heater is not going to be used for a long period, disconnect it from the
power supply.
16.
Always disconnect the heater before doing any maintenance
CAUTION - Some parts of this product can become very hot and cause
burns. Particular attention has to be given where children and vulnerable
people are present.
2. ELECTRICAL INSTALLATION NOTES
The installation should always be carried out by a qualified electrician or
a competent person in accordance with the current electrical standards:
HD 384 CENELEC for Mainland Europe, IEC 60446 and BS 7671 for the
United Kingdom, IEC 60445(2010) & ET101:2008 for Ireland and IEC 60364-7-708 1988
Internationally. The energy supply to the heater must always be properly earthed. The
heater must be connected to the energy supply using the provided cable.
An overvoltage category III Combined Circuit breaker and Residual
Current Device (RCD) with rated earth leakage operation not exceeding
30mA must be fitted upstream on the supply line. The circuit breaker
must have a contact opening distance of at least 3 mm.
•
The heaters should always be used with the mounting feet provided
•
Under no circumstances turn the heater on if it is not mounted using the Feet
supplied or if the face of the heater is on any surface.
•
The heater must not be recessed in the ceiling. There must be enough space
around the top of the heater to ensure adequate ventilation.
•
A minimum air gap of at least 90 cm should always be allowed between the top
of the heater and a ceiling or roof.
•
A distance of at least 100 cm should always be left in front of the heaters to
ensure safety
•
The Heater must not be located either directly below, or in front of a socket-
outlet.
•
The heater must not be used in a bathroom.