Page 1: ...FPH1000T FPH1500T FPH2000T Toledo Panel Heater INSTALLATION OPERATION MAINTENANCE MANUAL Class I IP 20 This Product is only suitable for well insulated spaces or occasional use ...

Page 2: ... under supervision or after they have been instructed relating to the safe use and have understood the potential dangers Children should not play with the Heater 5 Cleaning and maintenance must be performed by the user and not by unsupervised children 6 Children aged between 3 and 8 years of age shall not plugin regulate clean the heater or perform maintenance Children of less than 3 years should ...

Page 3: ...dom IEC 60445 2010 ET101 2008 for Ireland and IEC 60364 7 708 1988 Internationally The energy supply to the heater must always be properly earthed The heater must be connected to the energy supply using the provided cable An overvoltage category III Combined Circuit breaker and Residual Current Device RCD with rated earth leakage operation not exceeding 30mA must be fitted upstream on the supply l...

Page 4: ...he heater from the box and place the upper packaging on the ground Turn the heater upside down and place the top of the heater into the packaging to prevent any scratching of the upper surfaces With the openings at the bottom of the heater pointing upwards and the outlet grille facing towards you insert the feet with the wheels pointing in an upward direction and the hooks on the feet pointing tow...

Page 5: ...tion or Timer position When the switch is in the On position the heater will operate continuously under the control of the thermostat knob once a heat output is selected To select a heat output turn on either of the red neon switches on the right side of the heater Turning on one switch will operate half heat both switches on together will give full output This selection and also the thermostat wo...

Page 6: ...t failure To clean the outside of the appliance wipe off dirt with a damp cloth 7 TECHNICALFEATURES Product Code FPH1000T FPH1500T FPH2000T Power W 500W 1000W 750W 1500W 1000W 2000W Voltage V 220 240V 220 240V 220 240V Frequency Hz 50 60Hz 50 60Hz 50 60Hz Element Finned Aluminium Finned Aluminium Finned Aluminium Thermostat Adjustable Adjustable Adjustable Safety Cut out 75 C 85 C 90 C Size LxDxH ...

Page 7: ... 2 0kW Auxiliary electricity consumption At nominal heat output elmax N A At minimum heat output elmin N A In standby mode elSB 0 05 kW Type of heat output room temperature control Mechanic Thermostat Room Temperature Control Other control options N A ATC Electrical and Mechanical ATC House Broomhill Drive Tallaght D24 EF99 Ireland Tel 353 0 1 462 5111 UK Tel 44 0 203 5649164 Fax 353 0 1 452 0887 ...

Page 8: ... their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial waste for disposal 10 GUARANTEE Your appliance is guaranteed for 3 years during this period we will repair or exchange at our discretion any faulty or defective parts providing the appliance has been used in accordance with the operating installation instructions and h...