INSTALLATION INSTRUCTIONS - 5708A SERIES

 

 

   

        

       

        

 

Run Mode:

Function:

Program terminal: Terminals 3 and 4 controls when timing starts, counting, or where the frequency is applied.
Enable terminal: Terminals 2 and 4 controls the reset button on the front of the unit when it is enabled or disabled. 
Reset terminal: Terminals 1 to 4 controls the remote reset function.

Rising edge

: a.) When terminals 3 and 4 close, the count will increase by 1 on the display.                               

                      b.) When terminals 3 and 4 open, the display remains unchanged.
              

Falling edge

: a.) When terminals 3 and 4 close, the display remains unchanged.

         b.) When terminals 3 and 4 open, the count will increase by 1 on the display.                               

*Note

: The input terminal must be open when the external reset is pressed in the counter mode (FUNC-201 to FUNC-206).

Specifications:

Input: 

 TTL

Front Panel:  

IP66

Cutout:

  22mm x 45mm

Weight:

  ˜ 33g / 0.07lbs

Operation Temperature: 

 -10°C to 55°C

Storage Temperature:

  -25°C to 85°C noncondensing

FUNC-101~FUNC-115

: Timer Functions

FUNC-201~FUNC-206

: Counter Functions

FUNC-207

: Frequency Meter 

FUNC-208

: Tachometer 