INSTALLATION INSTRUCTIONS - 5708A SERIES
Run Mode:
Function:
Program terminal: Terminals 3 and 4 controls when timing starts, counting, or where the frequency is applied.
Enable terminal: Terminals 2 and 4 controls the reset button on the front of the unit when it is enabled or disabled.
Reset terminal: Terminals 1 to 4 controls the remote reset function.
Rising edge
: a.) When terminals 3 and 4 close, the count will increase by 1 on the display.
b.) When terminals 3 and 4 open, the display remains unchanged.
Falling edge
: a.) When terminals 3 and 4 close, the display remains unchanged.
b.) When terminals 3 and 4 open, the count will increase by 1 on the display.
*Note
: The input terminal must be open when the external reset is pressed in the counter mode (FUNC-201 to FUNC-206).
Specifications:
Input:
TTL
Front Panel:
IP66
Cutout:
22mm x 45mm
Weight:
˜ 33g / 0.07lbs
Operation Temperature:
-10°C to 55°C
Storage Temperature:
-25°C to 85°C noncondensing
FUNC-101~FUNC-115
: Timer Functions
FUNC-201~FUNC-206
: Counter Functions
FUNC-207
: Frequency Meter
FUNC-208
: Tachometer