background image

TABLE  C  (Cant) 

SINGLE-LINE  SET  CONNECTIONS 

MOUNTING  CORD  ARRANGEMENTS 

WITHOUT 

WITH 

MTG 

SPEAKERPHONE 

SPEAKERPHONE 

CORD 

D10S  OR  D10T 

(NOTE  1) 

COLOR 

MTG  CORD 

D20L  OR  D20M 

MTG  CORD 

V-0 

-15 

0

-V 

M1 

V-G 

T1 

G-V 

R1 

V-BR 

IT 

BR-V 

IR 

V-S 

Spare 

AG 

S-V 

Com 

COM 

Notes: 

1.  Certain  speakerphone  leads  are 

insulated  and stored  and  must be 

connected  as  shown  in  Fig.  11 

and 12. 

TABLE  D 

ISS  3,  SECTION  503-550-101 

2.  Modify  set  for  single  line  service 

as follows: 

• 

Disconnect,  insulate  and  store 

(R-G) and (G-R) key  leads  from 

9  and  10  of  front  terminal 
board. 

• 

Connect  stored  (BL-W)  key 
strap  to  9  of  front  terminal 
board  and  (W-BL)  strap  to  10 
of front  board. 

• 

Remove,  insulate  and  store 

(BR-V) key lead  from 8 of front 

terminal  board.  Connect  stored 

(\V-0) 

key  strap  to  8  of  front 

board. 

• 

When  internal  speakerphone  is 

furnished,  disconnect,  insulate 
and  store  ( Y-G)  (G-Y)  hold 
lamp  leads  from  terminals  1 

and  10 of rear board. 

CONNECTIONS  FOR  1A  KTS  AND/OR  STATION  BUSY  LAMP 

LINE 

HOLD 

MOUNTING 

STATION 

SWITCH 

KEY 

CORD 

DIODE 

M1W 

BUSY 

KS-15724, 

CORD 

LAMP 

BR 

V-BR 

BL 

Y-BR 

V-S 

L1 

NOTE  2 

Without 

1A 

L2 

1A1-1A2 

L2 

With 

1A 

11 

L2 

L2 

L2 

L2 

1A1-1A2 

L2 

L2 

L2 

*Insulated  and stored. 

Notes_-

1.  Numbered  terminals  are  on  the  front  terminal  board.  Lettered  terminals  are  on  the 

network. 

2.  Connection  shown  is  for  speakerphone.  If  speakerphone  is  not  furnished,  insulate  and 

store  lead. 

Page  11 

SSP S03-550-101-i03_1970-12-ll.jpg  Scanned by Frank Harrell,  (Cowboy  Frank) Castle Rock, Colorado  Apr 29,2012  21:38:44 

Summary of Contents for Call-a-matlc 2671B1M

Page 1: ...1A2 or 6A KTS with or without speakerphone and station busy lamp Note Speakerphone can be either internal or external Ordering Guide Note When ordering a 2671B1M telephone set depending on the servic...

Page 2: ...5081 FACEPLATE Page 2 39A POWER UNIT MOUNTING CORDS Fig 2 Station Modular Arrangement 2671B1M Telephone Set BSP S03 550 101 i03_1970 12 02 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorad...

Page 3: ...er e1oudspeaker 760A phone e Unit Control 5 5 B or modified5 5A eTransformer 2012 B eSix service configurations by addition of modular and optional items to 2671B1M telephone set Table A eChoice of ca...

Page 4: ...Requires a P 90D234 relay assembly and external 6668 transmitter Relay assembly is in stalled in place of 6748 transmitter Operating Features a 518 Dial eRECORD button when pulled places 518 dial in r...

Page 5: ...front of the network Fasten guard with two screws supplied with the telephone set and connect leads as shown in Table G 3 Mount the KS 8109L2 buzzer if required to the plastic block on left side of 35...

Page 6: ...ided the collar buttons and caps must be removed from the 63 5 type key before installing the250 type faceplate Note 63 5 type key is left in place but is electrically inoperative Rewire set as shown...

Page 7: ...e in Typewriter and that the plug is placed in the proper receptacle Either error will cause circuitry problems and extreme difficulty in removing the plug 3 06 When selecting a location for installin...

Page 8: ...portion island between YZ and 1 appears 4 Peel off existing designation strip starting at island 5 Start new strip at island and apply while rotating thumbwheel 6 Replace faceplate which should resto...

Page 9: ...one is heard depress CALL button again to complete dialing ISS 3 SECTION 503 550 101 Note If it is desired to bypass the access code for example with night service push CALL button before lifting hand...

Page 10: ...replacing set install customer s indexed cartridge in new set to avoid necessity of entering listings on new cartridge 5 04 If51B dial is not operating properly 1 Check power supply to set 2 Look for...

Page 11: ...store BR V key lead from 8 of front terminal board Connect stored V 0 key strap to 8 of front board When internal speakerphone is furnished disconnect insulate and store Y G G Y hold lamp leads from...

Page 12: ...PHONE LEAD SUPPLY MTG CD CONDUCTOR SET TERMINAL DESIGNATION TERMINAL PIN COLOR J2 AC AC 41 Y BL 16 AC AC 16 BL Y 14 COM GRD 25 S V 17 Caution Proper supply connections must be made as shown in Table F...

Page 13: ...HONE AI LEAD AT EQUIPMENT 4 IF POLARITY GUARD IS REQUIRED SEE TABLE G r IJ I WI R SI 5 R IS YI GJ BL R T q FRONT TERMINAL BOARD NOTE II 0 0 0 6 NOTE 5 NOTE 1 0 7 L RO R4 R2 K RS Ql w A a_ R7 R3 H RB l...

Page 14: ...CONNECTOR 4 IF POLARITY GUARD IS REQUIRED SEE TABLE G 5 LEADS ARE INSULATED AND STORED AND MUST BE TERMINATED AS SHOWN INSULATE AND STORE OPTIONS lA KTS IAI OR IA2 KTS 20128 TRANSFORMER FRONT TERM BOA...

Page 15: ...AND P 900212 CORD ASSEMBLY ARE OENTICAL 2 LINE SWITCH OPERATING SEQUENCE abBREAKS be MAKES de MAKES lq BREAKS WHEN RESTORING HANDSET d MUST BREAK BEFORE be BREAKS INSULATE AND STOR t SPARE TERMINAL OR...

Page 16: ...BLI S V REAR TERMINAL BOARD 900212 CORD SSEMSLY 050A8 MT G CORD EXTERNAL I SEE NOTE I FIGIMI I 1 I I 45 2021 4644 41 16 25 49 47 17 22 42 I 23 26 27 28 3 4 29 5 50 31 6 1 32 8 33 54 9 10 35 H 36 3712...

Page 17: ...8244318 H 1 ___ h 50 2 23 26 27283 4 Jfujuj _ j J f _j_lj _fJ J 11 u 1 I 1 1 I t 11 RINGER 39A POWER SPEAKERPHONE IA II I OR IA2 LEADS SUPPL1 LINE CKT 29 5 30 31 6 7 32 833 34 9 10 35 II 36 37 1213 19...

Reviews: