ATAGO PAL-1 BLT/ i Instruction Manual Download Page 2

20.4

b

.

l

.

t

20.4

1 2.3

20.4

1 2.3

dEL

E nd

dEL

y _n

dEL

d EL

PAr

PAr

PAr

blt

Pair

Export and Delete data history

Export data by 
long pressing  

e

.

Cancel the transfer 
by 

e

.

Transferred.

Tap on     .

3.

4. Verify imported data.

Verify the data transfer before deletion.

1.

Press 

f

 

and 

e

.

1.

2.

Data history
To save data history.

①Tap on     .
②Tap on Save.

To export data history

①Tap on    .
②Paste to email application.

③Send.

Export data history

Deleting data history

Export
from
PAL

iPhone
import

iPhone

2. Hold

e

 

.

Delete or Save data history.

Tap on 
the icon and launch 
ATAGO Logger.

Feature

 time,data,Temp
 2014/05/30 14:53:05,000,23.4,
 2014/05/30 14:58:05,AAA,23.4,
 2014/05/30 15:03:05,37.1,23.5,

:

:

5.

Incase 

Connection is Unsuccessful

6.

Connection is 
Unsuccessful *1

*1 

no

yes

End import

Start import

Connecting

Not Found

Disconnect

Bluetooth Pairing Request

Cancel

“PAL-BLT” would like to pair  

with your iPhone.

Initial setting

Please refer to the ATAGO Logger user manual for operational 
instructions.
The PDF user manual will begin to download from ATAGO website 

by tapping on Settings >User Manual. 

N

To cancel operation, press  

.

N

To enable the Bluetooth, flip the On/Off button

 in General > Bluetooth. 

N

PAL

Press 

f

 

.

Press the Home
button.

1.

Tap on PAL-BLT      .

3.

Tap on Forget this Device.

4.

¨

¨

¨

i

2.

Tap on Settings

Tap on Bluetooth.

Saved file can be 

imported from iTunes.

N

PAL-1 BLT/ i features Bluetooth capability to wirelessly 
communicate with peripheral devices.

The data can be exported and saved as a CSV file using ATAGO 

Logger for iPhone.

  

    Compatible devices: iPhone 4s, iPhone 5, iPhone 5s, 
    

Compatible devices: 

iPhone 5c, iPhone 6

    Compatible operating system: iOS 7 or newer

The application is available for download 

at iTunes App Store. 

EASY OPERATION

Save maximum of 100 measurements, 

with date and time. 

Delete

Save

Note

Dones

11:20

2014/06/30 15:11:11,LLL,20.0,
2014/06/30 15:11:58,6.6,20.0,
2014/06/30 15:30:02,AAA,20.0,

time,data,Temp
2014/06/31 09:11:11,LLL,20.0,
2014/06/31 09:11:58,6.5,20.0,
2014/06/31 09:13:50,6.6,20.0,
2014/06/31 09:14:00,6.8,20.0,

ATAGO Logger

20.4

0

0.0

0

01

---

℃ 

20.4

0.

0.0

20.4

00 0

0

02

---

20.4

1 2.3

20.4

L LL

Lo

LLL

1 2.3

20.4

H HH

n nn

HHH

1 2.3

blt

E rr

20.4

E EE

20.4

1 2.3

20.4

1 2.3

99

1 2.3

99

12

31

24

60

3.

1.

2.

1.

2.

4.

1.

2.

3.

N

0

9

0

9

1 12

0

3

0

9

0

23

0

5

0

9

m

m

m

m

m

N

m

Date and time setting is required when using for the first time.

Zero-set the instrument at the beginning of each day before use as well as after replacing the batteries.

Zero-setting

Zero-setting

Measurement

Number of measurements stored (Maximum: 100)

Initial measurements may fluctuate with hot or cold samples. Wait for 
the instrument to acclimate to the sample temperature, approximately 

20 seconds, to press          . Alternatively, press          multiple times 

until measurements become stable.

Wipe off the sample, rinse with water, and 
wipe off the water to clean the sample 
stage thoroughly.

Do not splash water above 50ºC. 

When hot water is necessary to clean off hardened samples, use water-soaked 
gauze around the prism area and keep hot water away from the body case. 

Do not use metal tools to apply samples on the prism as they may scratch the 
prism.

When the O-ring on the cover is 
dirty or damaged, the water 
resistance may be compromised. 
Lubricate the O-ring regularly.

For oily samples:

Dry the sample stage completely 
with dry tissues.

Clean oily residues with ethyl alcohol or 
mild soap, and then, rinse with water.

Mild 

soap

O-ring

Ethyl 

alcohol

The

 

displayed

 

temperature

 

is

 

that

 

of

 

the

 

prism

 

and

 

may

 

not necessarily 

match the temperature of the sample.

The

 

instrument

 

will turn

 

itself off

 

after

 

2

 

minutes

 

of

 

inactivity.

 

To

 

manually 

turn it off, hold down          for more than 2 seconds.

Measurement data Full. Oldest measurements will be 

overwritten and replaced by new measurements. 

02

Full

Press 

f

.

Press 

e

 

“000” blinks

 

twice.

Apply tap/
distilled water.

Zero-set correctly

Proceed to Export data history

Measurement value is displayed

Proceed to Measurement

Zero-setting is complete

Measurement: not 0.0%

Wipe the 
prism clean.

Press 

f

.

Apply sample.

Approx. 2 mm

Approx. 0.3 ml

of water

Approx. 0.3 ml

of sample

Approx. 2 mm

Wipe the 
prism clean.

Press 

e

 until the

 desired number is displayed.

Hold 

f

 

and 

e

.

Year:

Hour:

Month:

Day:

Minute:

S

econds: 

Fixed 00

Year

Hour

Confirm

Confirm

Confirm

Confirm

Confirm

Month

Day

Minute

Display

Set date and time before exporting data. 

Reset date and time if battery is taken out of the device for an extended period. 

Failed to connect to Bluetooth or 
data export error. 

The prism temperature is above the 

temperature range.

The instrument is faulty. 

(Replace the batteries. Contact 

ATAGO if this error persists.)

The sample is outside the 

measurement range.

The prism temperature is below 

the temperature range. 

Too

 

much

 

light

 

is

 

entering

 

the

 

prism,

 

and

 

the

 

instrument

 

cannot

 

measure

 

accurately.

 

(Shade

 

the

 

sample

 

stage

 

with

 

your

 

hand

 

and

 

take

 

a

 

measurement

 

again.)

f

 was pressed with nothing 

or an insufficient amount of sample 

on the prism.

e

 was pressed with nothing 

or something other than water 

on the prism.

The following messages alert the user when an operation has failed.

The battery is low.

*

Zero-

setting and Measurement

Date and time setting

Erorr Messages

Cleaning

LLL:

 

HHH:

 

OOO:

 
 

 

AAA:

 

 

nnn:  

Lower limit
error.

 

Upper limit
error.

 

Zero setting
complete.

 

Zero setting
error.

 

External 
light error.

History:

Date and 

time

Brix

 

(%)

Temperature

(ºC)

11:20

Log Data

time,data,Temp
2014/06/30 15:11:11,LLL,20.0,
2014/06/30 15:11:58,6.6,20.0,
2014/06/30 15:30:02,6.7,20.0,
2014/06/30 15:31:03,AAA,20.0,
2014/06/30 15:32:44,OOO,20.0,
2014/06/30 15:40:09,nnn,20.0,
2014/06/30 15:50:33,31.0.20.0,
2014/06/30 15:51:00,31.1,20.0,

time,data,Temp
2014/06/31 09:11:11,LLL,20.0,
2014/06/31 09:11:58,6.5,20.0,
2014/06/31 09:13:50,6.6,20.0,
2014/06/31 09:14:00,6.8,20.0,

11:20

File Menu

Clear

Save

Back

Try stirring the sample on the sensor while measuring 
to improve the repeatability of oily/fatty samples.

20.4

A AA

11:20

Log Data

time,data,Temp
2014/06/30 15:11:11,LLL,20.0,
2014/06/30 15:11:58,6.6,20.0,
2014/06/30 15:30:02,6.7,20.0,
2014/06/30 15:31:03,AAA,20.0,
2014/06/30 15:32:44,OOO,20.0,
2014/06/30 15:40:09,nnn,20.0,
2014/06/30 15:50:33,31.0.20.0,
2014/06/30 15:51:00,31.1,20.0,