EN 8
INSTALLATION
General
This appliance must be connected to the power supply by a recognised
installer who is familiar with and works in accordance with the
applicable safety regulations. This appliance conforms to the European
directives.
Important information:
• The lowest part of the cooker hood must be at least 65 cm above
a gas hob. The lowest part of the cooker hood must be at least 50
cm above an electric, ceramic or induction hob.
• The cooker hood may only be connected to an existing exhaust
duct to which no other appliances are connected (such as a geyser
or heater).
• Gas appliances must be vented in accordance with the local
regulations.
• The cooker hood works best when connected to an exhaust duct
that is as short and as straight as possible.
• Before drilling any holes, always check to make sure that there are
no wires in the area.
• The hood's connection pipe has a diameter of 150 mm. The
exhaust duct should preferably be of the same diameter.
• The installation materials supplied with this cooker hood are
suitable for reinforced concrete and masonry walls. You will need
special plugs and screws to fasten the appliance to some other
types of wall.