Carefully read the following important information regarding installa-
tion safety and maintenance. Keep this information booklet accessible
for further consultations.
The appliance has been designed as a exhausting version (external
exhaust), as a filter version (internal air recycle) cooker hood or as
use in homes with centralised vacuum system.

SAFETY PRECAUTION

1. 

ake care when the cooker hood is operating simultaneously with an

open fireplace or burner that depend on the air in the environment and

are supplied by other than electrical energy, as the cooker hood removes

the air from the environment which a burner or fireplace need for

combustion.

The negative pressure in the environment must not exceed 4 Pa (4 x 10

-5 bar).

Provide adequate ventilation in the environment for a safe operation of

the cooker hood.

Follow the local laws applicable for external air evacuation.

2.  WARNING!!

In certain circumstances electrical appliances may be a danger

hazard.

A) Do not check the status of the filters while the cooker hood

is operating

B) Do not touch the light bulbs after appliance use

C) Flambè cooking is prohibited underneath the cooker hood

D) Avoid free flame, as it is damaging for the filters and a fire

hazard

E) Constantly check food frying to avoid that the overheated oil

may become a fire hazard

F) Disconnect the electrical plug prior to any maintenance.

INSTALLATION INSTRUCTIONS

• Electric Connection
The appliance has been manufactured as a class II, therefore no earth
cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indicated on the
description label. Where a plug is provided, the cooker hood must be
installed in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between
contacts, in line with the electrical load and local standards, must be
placed between the appliance and the network in the case of direct
connection to the electrical network.

• The appliance must be installed at a minimum height of 700 mm from
an cooker stove in case of a gashob or an electrical hob.
If a connection tube composed of two parts is used, the upper part must
be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor used
to circulate hot air or for evacuating fumes from other appliances
generated by other than an electrical source.

• ATTENTION: should the lamps not work, make sure they are well
tightened.

 INSTALLATION
The following instruction should be followed to carry out the correct
installation of the cooker hood.
1)

Mounting of the cooker hood on the lower side of the cupboard.

2)

Selection of the version  (extraction or filtration)

Mounting the cooker hood on the lower side of the cupboard.  This
appliance must be fitted to a cupboard or other suitable support.  For
fixing use 4 screws suitable for the cupboard, using the hole in Fig.1.
When mounting align the front of the cooker hood to the door of the
cupboard and regulate the L wall spacer through  the screws marked
P (Fig 3).  The rear of the appliance must then align with the cupboard.

• EXTRACTION THROUGH AN OUTSIDE WALL
The appliance expels the fumes through an outside wall or a duct.  It is
necessary to buy a telescopic pipe in accordance with the standards
in use (inflammable with diameter 120mm)  and connect it to flange B
(Fig 4).

• RECIRCULATION
To transform the cooker hood from the extraction version to the re
circulating one ask your supplier for an activated carbon filter.  The
activated carbon filter cleans the air of the room.  This filter is not
washable or  re-usable and must be substituted at least every 4 months.
Saturation  of the activated charcoal depends on how often the appliance
is used, the type of kitchen and how regularly the grease filter is cleaned.
The filter must be fitted to the extracting group cooker hood in the
centre of the fan grille by twisting it by 90 degrees until it is gripped
securely.  For this operation remove the grill G (Fig 3).  The clean air
is returned into the room through a connecting tube passing inside the
cupboard and connected to the ring B (Fig 5).

• CENTRALISED VACUUM SYSTEM (WV6011AC-WV6055AC)
The switch controls the opening and closing of a valve by means of a
thermoelectric device. By turning the switch to ON position, after a
minute, the valve opens and turns by 90°, with extraction of bad air. By
turning the switch to OFF position, after about 100 seconds, the valve
closes.

If you have the model with centralised vacuum system it is necessary
to follow the indications in the wiring diagram (Fig.2).

USE AND MAINTENANCE

• It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes
after cooking is terminated in order to completely eliminate cooking
vapours and odours.
The proper function of the cooker hood is conditioned by the regularity
of the maintenance operations, in particular, the active carbon filter.

• The anti-grease filters capture the grease particles suspended in the
air, and are therefore subject to clogging according to the frequency of
the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the filter
at a maximum of 2 months by carrying out the following instructions:
- Remove the filters from the cooker hood and wash them in a solution
of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes. This
is not cause for customer complaint nor replacement of panels.

•  The active carbon filters purify the air that is replaced in the
environment.  The filters are not washable nor re-useable and must be
replaced at maximum every four months. The saturation of the active
carbon filter depends on the frequency of use of the appliance, by the
type of cooking and the regularity of cleaning the anti-grease filters.

•  Clean the fan and other surfaces of the cooker hood regularly using
a cloth moistened with denatured alcohol or non abrasive liquid
detergent.

THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.

ENGLISH

7

Summary of Contents for WV6011AC

Page 1: ... en installatievoorschrift afzuigkap mode d emploi et d installation hotte de cuisine Montage und Bedienungsanleitung Dunstabzugshaube instructions for use and installation cooker hood WV6011AM WV6055AM WV6011AC WV6055AC ...

Page 2: ...L L N N BLUE BROWN SKY BLUE RED BLACK WHITE GREY VIOLET SWL BLUE BROWN BROWN BLUE BLUE ELECTRO VALVE 5 mSWM 6 4 8 7 9 6 5 4 RED BLACK WHITE mSWL 6 4 5 Fig 2 Fig 1 min 20 max 40 12 420 165 135 30 512 21 5 21 5 469 120 290 600 270 131 65 31 31 258 ...

Page 3: ...3 A G P L P B 420 B B 420 Fig 3 Fig 4 Fig 5 ...

Page 4: ...r het type kastje De gaten maken volgens het schema in fig 1 Voor een juiste montage de voorkant van de afzuigkap met het deurtje van het keukenkastje uitlijnen De afstandstrip L monteren en uitlijnen daarna vastzetten met schroeven P fig 3 AFZUIGEN NAAR BUITEN Het apparaat voert de dampen af naar buiten door de buitenmuur of een schoorsteen Hiervoor is een pijp benodigd met een diameter van 120 m...

Page 5: ...rtie postérieure de l appareil au meuble VERSION ASPIRANTE Avec ce genre d installation l appareil évacue les vapeurs à l extérieure à travers une paroi périmètrale ou une canalisation déjà existente Il est donc nécessaire de se procurer un tube mural télescopique du type prévu par les normes en vigueur non inflammable de Ø 120mm et reliez le à la bride B fournie Fig 4 VERSION FILTRANTE Pour trans...

Page 6: ...rätes andasMontagepaneelanzupassen ABLUFTVERSION Bei dieser Betriebsweise werden die angesaugten Dämpfe durch die AußenwandoderdurcheinAbluftrohrinsFreiegeleitet ZudiesemZweck muß ein normgerechtes nicht entflammbares Rohr mit Durchmesser Æ 120 mm besorgt und an den vorgesehenen Anschlußflansch B Abb 4 angeschlossen werden FILTERVERSION Um die Abzugshaube von Abluftbetrieb auf Umluftbetrieb umzust...

Page 7: ...gulate the L wall spacer through the screws marked P Fig 3 The rear of the appliance must then align with the cupboard EXTRACTION THROUGH AN OUTSIDE WALL The appliance expels the fumes through an outside wall or a duct It is necessary to buy a telescopic pipe in accordance with the standards in use inflammable with diameter 120mm and connect it to flange B Fig 4 RECIRCULATION To transform the cook...

Page 8: ...ositie 4 Positie 7 Zolder Keuken Wasemkap Nul fase Nul Let op positie 1 5 en 8 doorverbinden met fase Bij deze aansluiting draait het centraal afzuigsysteem altijd door op nachtstand Aansluiting WV6011AC WV6055AC ...

Page 9: ...3LI0S3A7 ...

Reviews: