EN 14
Connection
Electrical connections
This appliance is a Class I appliance and must be earthed.
Check to make sure that the voltage specified on the type plate
matches the mains voltage. The appliance must be connected to the
mains as follows:
BROWN = L (live)
BLUE = N (neutral)
GREEN/YELLOW = Earth
This cooker hood is fitted with a plug. Install the cooker hood so that
the plug is accessible. It is preferable to fit the wall socket out of sight,
behind the chimney cover.
Note:
When you make a fixed connection to the mains you must make
sure that the live wire is connected to an omnipolar switch with a break
contact distance of at least 3 mm.
Max. 125 cm
Mounting the cooker hood
The last pages of this manual show the steps for mounting the
cooker hood.
INSTALLATION
Summary of Contents for WS80 DM Series
Page 16: ...NL 16 ...
Page 30: ...FR 16 ...
Page 44: ...DE 16 ...
Page 58: ...INSTALLATIE INSTALLATION 16 INSTALLATIE INSTALLATION 320 500 360 157 210 360 367 ...