36
Installation and connection information
DISHWASHER CAVITY MEASUREMENTS
38 mm
50-105 mm
W = 600 mm
M
in 560mm
H = M
in 863 mm
WATER CONNECTION
•
Connect to hot or cold water?
If you use oil or electricity to heat your home:
Connect the dishwasher to the cold water sup-
ply.
If, on the other hand, you use district heating,
solar power or geothermal power:
Connect the dishwasher to the hot water sup-
ply (max. 70°C).
• The inlet pipe has a connector with either a
3/4” internal thread.
DISHWASHER MEASUREMENTS
Min 863
Min 560
600
135-185
50
50-105
596
860-910
520
With nut and sliding protection mounted
Recommended measurements
*
*
*
*
* *
560
ELECTRICAL CONNECTION
• 220-230VAC mains voltage, minimum 15A
DRAINAGE
• The supplied cone-shaped connection pipe fits
a drainage connection with an internal diam-
eter of 13, 16, 18 and 22 mm.
• Use a hose clamp if connecting to a fixed drain
(sink).
The connector is ready to cut to the desired
drain connection size. Only a clamp is required.
TOOLS
1) Flathead screwdriver
2) Open-ended spanner 16 mm
3) Tape measure
4) Spirit level
CABLE/HOSE LENGTHS
Drainage hose: 1930 mm
Supply hose: 1670 mm
Power cable: 1770 mm
Make sure the edges of the
cable hole are even so as not
to damage the drainage and
supply hoses and the electric
cable.
Cable hole