GB 16
The fitting of the appliance should only be carried out by a registered
Corgi gas fitter.
please note
The type of gas and the country for which the appliance has been
designed are indicated on the ratings plate.
This is a category 3 appliance.
gas connection
The gas connection must comply with national and local regulations.
We recommend that the hob be connected by means of a fixed pipe.
Connection using a specially designed safety hose is also permitted.
Behind an oven use must be made of a pipe made entirely out of metal.
please note
A safety hose may not be bent and must not come into contact with
moving parts of kitchen units.
In all cases the connection tap for the appliance must be positioned such
that it is easily accessible.
Before using the appliance for the first time check the connections using
water and washing-up liquid to ensure that there are no gas leaks.
INSTALLATION INSTRUCTIONS