GB 10
assembly
The most important dimensions are shown on the previous
page. You can set the height of the telescopic pipe. Take the
allowable tolerances into account.
Position the discharge and the electrical connection in such
a way that it will be easy to hook up the hood.
Tip:
Before starting to drill, check that there are no
installation pipes present.
1. Determine the place and height of the extractor hood
with respect to the hob. Account for the minimum
distance between the hob and the extractor hood (1).
2. Mark off the position of the 2 mounting holes for the wall
brackets (2) and the 4 mounting holes for the extractor
hood (3). The V-marking marks the middle of the bracket.
You may also use the 2 extra mounting holes on the back
of the extractor hood (4).
3. Drill the mounting holes and the push plugs into them.
4. Fit the extractor hood horizontally using the upper 2 key-
shaped holes of the motor housing.
5. Fix the extractor hood using the 2 lowermost holes in the
motor housing and (optionally) the 2 holes on the back of
the extractor hood (accessible via the filter openings).
6. Put the plug in the socket.
7. Connect the discharge hose (not supplied) to the
discharge pipe and the extractor hood.
general
mounting wall hood
70
1
2
3
3
4
4
88020554_HL_Centrallogic_GB.qxp 21-12-2006 09:28 Pagina GB 10